2011
Electrochemical Biosensor for Detection of Bioagents
ŠVÁBENSKÁ, Eva, David KOVÁŘ, Vít KRAJÍČEK, Jan PŘIBYL, Petr SKLÁDAL et. al.Základní údaje
Originální název
Electrochemical Biosensor for Detection of Bioagents
Název česky
Elektrochemický biosensor pro detekci biologických látek
Autoři
ŠVÁBENSKÁ, Eva (203 Česká republika, domácí), David KOVÁŘ (203 Česká republika, domácí), Vít KRAJÍČEK (203 Česká republika, domácí), Jan PŘIBYL (203 Česká republika, domácí) a Petr SKLÁDAL (203 Česká republika, garant, domácí)
Vydání
International Journal of Electrochemical Science, Belgrade, Serbia, ESG, 2011, 1452-3981
Další údaje
Jazyk
angličtina
Typ výsledku
Článek v odborném periodiku
Obor
10600 1.6 Biological sciences
Stát vydavatele
Česká republika
Utajení
není předmětem státního či obchodního tajemství
Odkazy
Impakt faktor
Impact factor: 3.729
Kód RIV
RIV/00216224:14310/11:00055984
Organizační jednotka
Přírodovědecká fakulta
UT WoS
000297571400002
Klíčová slova česky
amerometrický sensor; sítotiskové elektrody; imunochemický detektor; imunosensor
Klíčová slova anglicky
amperometric sensor; screen-printed electrode; immunochemical detector; immunosensor
Změněno: 16. 4. 2012 09:23, Ing. Andrea Mikešková
Anotace
V originále
Simple and rapid detection and identification of dangerous bioagents is important for preventing illness or even death of people due to infectious diseases and bioterrorist threats. Electrochemical detection has a large potential for development of portable instrumentation suitable for analysis in field and especially combination with specificity of immunoassays seems promising. Initially, the construction of the immunosensing layer was realised and the effect of Au nanoparticles on the response of peroxidase was studied. An amperometric immunosensor was developed using screen-printed transducer, it employed specific capture of microbes in the sensing area by formation of an immunocomplex and its subsequent labelling using the tracer - antibody conjugated to peroxidase. The obtained sandwich electrochemical immunoassay was applied for the model microbial cells of B. subtilis. The total time of analysis was 20 min and the detection of cells below 104 CFU/ml was feasible. The presence of microbial cells at the sensing surface was confirmed using atomic force microscopy. The results appear promising for combination of the immunosensor with a cyclone sampler and analysis of Bacillus-based bioaerosols in field trials.
Návaznosti
LC06030, projekt VaV |
|