2012
Diode laser thermal vaporization inductively coupled plasma mass spectrometry
FOLTYNOVÁ, Pavla, Viktor KANICKÝ a Jan PREISLERZákladní údaje
Originální název
Diode laser thermal vaporization inductively coupled plasma mass spectrometry
Název česky
Diode laser thermal vaporization inductively coupled plasma mass spectrometry
Autoři
FOLTYNOVÁ, Pavla (203 Česká republika, domácí), Viktor KANICKÝ (203 Česká republika, domácí) a Jan PREISLER (203 Česká republika, garant, domácí)
Vydání
Analytical Chemistry, Washington, D.C., USA, American Chemical Society, 2012, 0003-2700
Další údaje
Jazyk
angličtina
Typ výsledku
Článek v odborném periodiku
Obor
10406 Analytical chemistry
Stát vydavatele
Spojené státy
Utajení
není předmětem státního či obchodního tajemství
Odkazy
Impakt faktor
Impact factor: 5.695
Kód RIV
RIV/00216224:14740/12:00057290
Organizační jednotka
Středoevropský technologický institut
UT WoS
000301021400026
Klíčová slova anglicky
Laser ablation; inductively coupled plasma; mass spectrometry; sample introduction; diode laser; pyrolysis; thermal vaporization
Příznaky
Mezinárodní význam, Recenzováno
Změněno: 10. 4. 2013 07:57, Olga Křížová
Anotace
V originále
An approach of sample introduction for inductively coupled mass spectrometry (ICPMS), diode laser thermal vaporization (DLTV) is described. The method allows quantitative determination of metals in submicroliter volumes of liquid samples. Laser power is sufficient to induce pyrolysis of a suitable substrate with the deposited sample leading to aerosol generation. Unlike existing sample introduction systems based on laser ablation, it uses a NIR diode laser rather than an expensive high-energy pulsed laser. For certain elements, this sample introduction technique may serve as an alternative to solution analysis with conventional nebulizers. Using a prearranged calibration set, DLTV ICPMS provides rapid and reproducible sample analysis (RSD 10%). Sample preparation is fast and simple, and the prepared samples can easily be archived and transported. The limits of detection for Co, Ni, Zn, Mo, Cd, Sn, and Pb deposited on the preprinted paper were found to be in the range of 0.4–30 pg. The method was characterized, optimized, and applied to the determination of Co in a drug preparation, Pb in whole blood, and Sn in food samples without any sample pretreatment.
Návaznosti
ED1.1.00/02.0068, projekt VaV |
| ||
GAP206/12/0538, projekt VaV |
| ||
GA203/09/1025, projekt VaV |
| ||
MSM0021622411, záměr |
| ||
MSM0021622412, záměr |
| ||
MSM0021622415, záměr |
|