BIDMANOVÁ, Šárka, Antonín HLAVÁČEK, Jiří DAMBORSKÝ a Zbyněk PROKOP. Conjugation of 5(6)-carboxyfluorescein and 5(6)-carboxynaphthfluorescein with bovine serum albumin and their immobilization for optical pH sensing. SENSORS AND ACTUATORS B: CHEMICAL. roč. 161, č. 1, s. 93-99. ISSN 0925-4005. doi:10.1016/j.snb.2011.09.046. 2012.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Conjugation of 5(6)-carboxyfluorescein and 5(6)-carboxynaphthfluorescein with bovine serum albumin and their immobilization for optical pH sensing
Autoři BIDMANOVÁ, Šárka (203 Česká republika, domácí), Antonín HLAVÁČEK (203 Česká republika, domácí), Jiří DAMBORSKÝ (203 Česká republika, garant, domácí) a Zbyněk PROKOP (203 Česká republika, domácí).
Vydání SENSORS AND ACTUATORS B: CHEMICAL, 2012, 0925-4005.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor Genetika a molekulární biologie
Stát vydavatele Švýcarsko
Utajení není předmětem státního či obchodního tajemství
Impakt faktor Impact factor: 3.535
Kód RIV RIV/00216224:14310/12:00062930
Organizační jednotka Přírodovědecká fakulta
Doi http://dx.doi.org/10.1016/j.snb.2011.09.046
UT WoS 000301549400007
Klíčová slova anglicky pH indicator Fluorescence Optical sensor Immobilization Conjugation Fluorescein
Štítky AKR, rivok
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Ing. Andrea Mikešková, učo 137293. Změněno: 22. 4. 2013 15:19.
Anotace
An approach for the immobilization of a pH indicator in optical pH sensors and biosensors was developed. Fluorescent dyes 5(6)-carboxyfluorescein and 5(6)-carboxynaphthofluorescein were conjugated with bovine serum albumin as a non-enzymatic scaffold protein and the conjugation procedure was optimized. Fluorescent properties, sensitivity to temperature and photostability of conjugates have been studied and characterized into details. The conjugates were immobilized on glass support by: (i) glutaraldehyde crosslinking or (ii) entrapment in sol–gel matrix ORMOCER with subsequent glutaraldehyde cross-linking. The response to pH and leaching potential were evaluated. The sensor layer, based on immobilized conjugates of 5(6)-carboxyfluorescein and bovine serum albumin, displayed rapid response over the pH range 4.0–9.0, making it compatible with a range of applications such as bioprocessing, clinical diagnostics or environmental monitoring. Immobilized conjugates of 5(6)-carboxynaphthofluorescein and bovine serum albumin showed an enhanced sensitivity in alkaline pH levels, response for glutaraldehyde crosslinking ranged from pH 9.1 to 11.0 and from 8.3 to 10.0 for the ORMOCER entrapment, however, control of the indicator leaching was essential.
Návaznosti
ED0001/01/01, projekt VaVNázev: CETOCOEN
VytisknoutZobrazeno: 23. 4. 2024 09:43