2012
Simultaneous determination of metal traces using SPE preconcentration on Amberlite XAD-7 by ICP-MS in environmental water and sample ecotoxicology assessment.
HOLUBOVA, Z., L. SOMMER, M. MOOS a Jan KUTAZákladní údaje
Originální název
Simultaneous determination of metal traces using SPE preconcentration on Amberlite XAD-7 by ICP-MS in environmental water and sample ecotoxicology assessment.
Autoři
HOLUBOVA, Z. (203 Česká republika, garant), L. SOMMER (203 Česká republika), M. MOOS (203 Česká republika) a Jan KUTA (203 Česká republika, domácí)
Vydání
Fresenius Environmental Bulletin, FREISING, Germany, PARLAR SCIENTIFIC PUBLICATIONS (P S P), 2012, 1018-4619
Další údaje
Jazyk
angličtina
Typ výsledku
Článek v odborném periodiku
Obor
10511 Environmental sciences
Stát vydavatele
Německo
Utajení
není předmětem státního či obchodního tajemství
Impakt faktor
Impact factor: 0.641
Kód RIV
RIV/00216224:14310/12:00063907
Organizační jednotka
Přírodovědecká fakulta
UT WoS
000312412700018
Klíčová slova anglicky
Solid Phase Extraction; Amberlite XAD-7; ICP-MS and Waters; Ecotoxicology
Změněno: 11. 4. 2013 17:27, Ing. Andrea Mikešková
Anotace
V originále
This study has been focused on the determination of nine trace elements Be-9, V-51, Co-59, Ni-60, Y-89, led, (208)pb, Th-232 and U-238 by inductively coupled plasma mass spectrometry (ICP-MS) in natural waters and water samples after mining and processing of uranium.An ICP-MS spectrometer Agilent 7500ce, with a plasma generator of 27.12 MHz, power output of 1500 W and concentric nebulizer MicroMist (TM) with a cooled Scott chamber was used. The nonspectral interferences were eliminated by using a solution of internal standards Li-6 for Be-9, Sc-45 (V-51), Ge-72 (Co-59, Ni-60, (89)y), Rh-103 (Cd-111), Bi-209 ((208)pb, Th-232, U-238) The spectral interferences were eliminated by using the Helium collision cell during measurement. Monitored interfering elements were K+, Na+, NH4+ Ca2+, Mg2+, Al3+, Fe3+ and Cl-, HCO3-, SO42-, PO43-. For the preconcentration polymeric sorbent Amberlite XAD-7 was used. Elements were retained as their chelates with different organic reagents: 4-(2-pyridylazo) resorcinol (PAR), 3,4-Dihydroxy-9,10-dioxo-2-anthracenesulfonic acid sodium salt (ALS), 8-Hydroxyquinoline-5-sulphonic acid (8HQS) and Ammonium pyrrolidinedithiocarbamate (APDC).The sorption process was studied under various conditions with respect to pH. Sorbents were also conditioned with different surfactants: Benzyldimethyltetradecylammonium chloride (Zephyramine), 1-etoxycarbonyl-pentadecyl-trimethyl-ammonium bromide (Septonex (R)), Brij 35 or Sodium Dodecylsulphate (SDS). Various elution mixtures were also tested, the best results were obtained for the mixture of acetone and ethanol (1:1) in the presence of 1 mol.l(-1) HCl. The excess of acid and organic solvents were evaporated in Teflon (R) dishes prior to the determination by ICP-MS. The Thamnocephalus platyurus as THAMNOTOXKIT F (TM), Daphnia magna as a DAPHTOXKIT F (TM) and Artemia sauna as Artoxkit M (TM) are organisms, which were used for ecotoxicology assessment of water samples after mining of uranium.
Návaznosti
ED0001/01/01, projekt VaV |
|