2013
Evaluation of the Efficacy of Additional Measures Introduced for the Protection of Healthcare Personnel Handling Antineoplastic Drugs
ODRÁŠKA, Pavel, Lenka DOLEZALOVA, Jan KUTA, Michal ORAVEC, Pavel PILER et. al.Základní údaje
Originální název
Evaluation of the Efficacy of Additional Measures Introduced for the Protection of Healthcare Personnel Handling Antineoplastic Drugs
Autoři
ODRÁŠKA, Pavel (203 Česká republika, garant), Lenka DOLEZALOVA (203 Česká republika), Jan KUTA (203 Česká republika, domácí), Michal ORAVEC (203 Česká republika, domácí), Pavel PILER (203 Česká republika, domácí) a Luděk BLÁHA (203 Česká republika, domácí)
Vydání
ANNALS OF OCCUPATIONAL HYGIENE, OXFORD, OXFORD UNIV PRESS, 2013, 0003-4878
Další údaje
Jazyk
angličtina
Typ výsledku
Článek v odborném periodiku
Obor
30104 Pharmacology and pharmacy
Stát vydavatele
Velká Británie a Severní Irsko
Utajení
není předmětem státního či obchodního tajemství
Impakt faktor
Impact factor: 2.068
Kód RIV
RIV/00216224:14310/13:00067961
Organizační jednotka
Přírodovědecká fakulta
UT WoS
000315158600008
Klíčová slova anglicky
chemical analysis; cytotoxic drugs; hazardous pharmaceuticals; occupational exposure; safety engineering
Příznaky
Mezinárodní význam, Recenzováno
Změněno: 4. 4. 2014 20:35, prof. RNDr. Luděk Bláha, Ph.D.
Anotace
V originále
Antineoplastic drugs are considered as a potential health risk to healthcare personnel, due to their adverse effects. The objective of the study was to compare the surface contamination level of the conventional preparation room and outpatient clinic before and after the implementation of a set of additional protective measures. To determine the surface contamination level with antineoplastic drugs, cyclophosphamide and platinum were determined in wipe samples with high performance liquid chromatography with tandem mass spectrometry and inductively coupled plasma mass spectrometry.In the preparation room, depending on the sampling spot and analyte, median concentrations ranged from 5 to 267 pg cm(2) and from 2 to 368 pg cm(2) before and after implementation of the measures, respectively. In the outpatient clinic, median concentrations ranged from 5 to 5310 pg cm(2) and from < 0.2 to 574 pg cm(2) before and after implementation of the measures, respectively. Depending on the sampling spot, median contamination of the outpatient clinic with cyclophosphamide and platinum was reduced by 5799% and 6198%, respectively.The measures implemented in the outpatient clinic were shown to reduce workplace contamination effectively. Therefore, they can be recommended also for other workplaces where antineoplastic drugs are administered. In contrast, measures implemented in the preparation room, where relatively strict regulations had already been adopted before the study, were less effective. To decrease the actual contamination of the preparation room, other protective measures (e.g. closed-system transfer devices) should be considered.
Návaznosti
ED0001/01/01, projekt VaV |
| ||
EE2.3.20.0053, projekt VaV |
| ||
LM2011028, projekt VaV |
|