ŠTĚPÁNKOVÁ, Kateřina, Karel NOVOTNÝ, Michaela VAŠINOVÁ GALIOVÁ, Viktor KANICKÝ, Jozef KAISER a David HAHN. Laser ablation methods for analysis of urinary calculi: Comparison study based on calibration pellets. Spectrochimica Acta B. Elsevier, 2013, roč. 81, MAR 1, s. 43-49. ISSN 0584-8547. Dostupné z: https://dx.doi.org/10.1016/j.sab.2012.12.009.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Laser ablation methods for analysis of urinary calculi: Comparison study based on calibration pellets
Autoři ŠTĚPÁNKOVÁ, Kateřina (203 Česká republika, domácí), Karel NOVOTNÝ (203 Česká republika, garant, domácí), Michaela VAŠINOVÁ GALIOVÁ (203 Česká republika, domácí), Viktor KANICKÝ (203 Česká republika, domácí), Jozef KAISER (203 Česká republika) a David HAHN (840 Spojené státy).
Vydání Spectrochimica Acta B, Elsevier, 2013, 0584-8547.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 10406 Analytical chemistry
Stát vydavatele Velká Británie a Severní Irsko
Utajení není předmětem státního či obchodního tajemství
Impakt faktor Impact factor: 3.150
Kód RIV RIV/00216224:14310/13:00066611
Organizační jednotka Přírodovědecká fakulta
Doi http://dx.doi.org/10.1016/j.sab.2012.12.009
UT WoS 000315314500006
Klíčová slova anglicky Laser ablation; LA-ICP-MS/OES; LIBS; LA-LIBS; Urinary calculi
Štítky AKR, rivok
Změnil Změnil: doc. Mgr. Karel Novotný, Ph.D., učo 17748. Změněno: 8. 2. 2018 10:02.
Anotace
Methods based on laser ablation, such as Laser-Induced Breakdown Spectroscopy (LIBS) and Laser-Ablation Inductively Coupled Plasma Mass/Optical Emission Spectrometry (LA-ICP-MS/OES) are particularly suitable for urinary calculi bulk and micro analysis. Investigation of spatial distribution of matrix and trace elements can help to explain their emergence and growth. However, quantification is still very problematic and these methods are often used only for qualitative elemental mapping. There are no commercially available standards, which would correspond to the urinary calculi matrix. Internal standardization is also difficult, mainly due to different crystalline phases in one kidney stone. The aim of this study is to demonstrate the calibration capabilities and examine the limitations of laser ablation based techniques. Calibration pellets were prepared from powdered human urinary calculi with phosphate, oxalate and urate matrix. For this comparative study, the most frequently used laser-ablation based analytical techniques were chosen, such as LIBS and LA-ICP-MS. Moreover, some alternative techniques such as simultaneous LIBS-LA-ICP-OES and laser ablation LA-LIBS were also utilized.
Návaznosti
ED1.1.00/02.0068, projekt VaVNázev: CEITEC - central european institute of technology
GA203/09/1394, projekt VaVNázev: Chemická, mineralogická a statistická analýza souboru močových konkrementů pacientů ostravské aglomerace
Investor: Grantová agentura ČR, Chemická, mineralogická a statistická analýza souboru močových konkrementů pacientů ostravské aglomerace
ME08002, projekt VaVNázev: Použití spektroskopie laserem buzeného plazmatu (LIBS) a laserové ablace ve spojení s ICP-OES/MS spektroskopií pro chemické mapování biominerálů
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, Použití spektroskopie laserem buzeného plazmatu (LIBS) a laserové ablace ve spojení s ICP-OES/MS spektroskopií pro chemické mapování biominerálů, Program výzkumu a vývoje KONTAKT (ME)
VytisknoutZobrazeno: 24. 5. 2024 13:55