DUŠA, Filip, Jana KŘENKOVÁ, Dana MORAVCOVÁ, Vladislav KAHLE a Karel ŠLAIS. Divergent-flow isoelectric focusing for separation and preparative analysis of peptides. Electrophoresis. Hoboken: WILEY-BLACKWELL, 2012, roč. 33, č. 12, s. 1687-1694. ISSN 0173-0835. Dostupné z: https://dx.doi.org/10.1002/elps.201100587.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Divergent-flow isoelectric focusing for separation and preparative analysis of peptides
Autoři DUŠA, Filip (203 Česká republika, domácí), Jana KŘENKOVÁ (203 Česká republika), Dana MORAVCOVÁ (203 Česká republika), Vladislav KAHLE (203 Česká republika) a Karel ŠLAIS (203 Česká republika).
Vydání Electrophoresis, Hoboken, WILEY-BLACKWELL, 2012, 0173-0835.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 10608 Biochemistry and molecular biology
Stát vydavatele Spojené státy
Utajení není předmětem státního či obchodního tajemství
WWW Full Text
Impakt faktor Impact factor: 3.261
Kód RIV RIV/00216224:14310/12:00081936
Organizační jednotka Přírodovědecká fakulta
Doi http://dx.doi.org/10.1002/elps.201100587
UT WoS 000305792500002
Klíčová slova anglicky Autofocusing; Caseinomacropeptide; Isoelectric focusing; Mass spectrometry; Peptides
Štítky AKR, rivok
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Mgr. Marie Šípková, DiS., učo 437722. Změněno: 17. 12. 2019 15:00.
Anotace
A divergent-flow isoelectric focusing (DF IEF) technique has been applied for the separation and preparative analysis of peptides. The parameters of the developed DF IEF device such as dimension and shape of the separation bed, selection of nonwoven material of the channel, and separation conditions were optimized. The DF IEF device was tested by the separation of a peptide mixture originating from the tryptic digestion of BSA, cytochrome c, and myoglobin. The pH gradient of DF IEF was created by the autofocusing of tryptic peptides themselves without any addition of carrier ampholytes. The focusing process was monitored visually using colored pI markers, and the obtained fractions were analyzed by RP-HPLC and ESI/TOF-MS. DF IEF operating in the autofocusing mode provides an efficient preseparation of peptides, which is comparable with a commercially available MicroRotofor multicompartment electrolyzer and significantly improves sequence coverage of analyzed proteins. The potential of the DF IEF device as an efficient tool for the preparative scale separations was demonstrated by the isolation of caseinomacropeptide (CMP) from a crude whey solution.
Návaznosti
IAAX00310701, projekt VaVNázev: Rychlá detekce a identifikace patogenních mikroorganizmů a virů pomocí elektromigračních technik a hmotnostní spektrometrie
Investor: Akademie věd ČR, Rychlá detekce a identifikace patogenních mikroorganismů a virů pomocí elektromigračních technik a hmotnostní spektrometrie
VytisknoutZobrazeno: 22. 7. 2024 06:31