New solution IEF device for micropreparative separation of peptides and proteins

DUŠA, Filip a Karel ŠLAIS

Základní údaje

Originální název

New solution IEF device for micropreparative separation of peptides and proteins

Autoři

DUŠA, Filip (203 Česká republika, domácí) a Karel ŠLAIS (203 Česká republika)

Vydání

Electrophoresis, Hoboken, WILEY-BLACKWELL, 2013, 0173-0835

Další údaje

Jazyk

angličtina

Typ výsledku

Článek v odborném periodiku

Obor

10608 Biochemistry and molecular biology

Stát vydavatele

Spojené státy

Utajení

není předmětem státního či obchodního tajemství

Impakt faktor

Impact factor: 3.161

Kód RIV

RIV/00216224:14310/13:00080516

Organizační jednotka

Přírodovědecká fakulta

UT WoS

000319939300009

Klíčová slova anglicky

Bioactive peptides; Caseinomacropeptide; Micropreparative; Solution isoelectric focusing; Whey

Štítky

Příznaky

Mezinárodní význam, Recenzováno
Změněno: 18. 12. 2019 13:13, Mgr. Marie Šípková, DiS.

Anotace

V originále

The article presents a new concept of preparative solution IEF where time requirements and efficiency are similar to gel-based IEF whereas simple fraction handling as well as quick and complete protein recovery typical for solution-based IEF methods are maintained. The presented method is based on the IEF in separation medium soaked in a segmented strip of nonwoven fabric. The strip is positioned in an open horizontal V-shaped trough. Suggested focusing method combines free solution IEF under continuous evaporation and whole channel dispensing. Separation medium based on ethylene glycol/water mixture enhances viscosity enough to reduce electroosmosis and prevents the medium from completely drying out. Generation of pH gradient and final local pH is visually traced by colored low-molecular pI markers added to input mixture, which enables an optimization of focusing process and collection of individual fractions at desired pH range. The proposed method was tested by fractionation of the proteins and bioactive peptides originating from raw whey. Moreover, subsequent HPLC analysis of the individually collected solution IEF fractions was used for identification of whey components. We confirmed that the method is capable to process directly few tenths of milliliters of raw samples including the salty ones.

Návaznosti

VG20112015021, projekt VaV
Název: Vývoj instrumentálních metodických postupů rychlé detekce a identifikace biologických agens v reálných vzorcích (Akronym: Detekce a identifikace biol. agens)
Investor: Ministerstvo vnitra ČR, Vývoj instrumentálních metodických postupů rychlé detekce a identifikace biologických agens v reálných vzorcích