LEE, K.T., S. HONG, J.S. LEE, K.H. CHUNG, Klára HILSCHEROVÁ, J.P. GIESY a J.S. KHIM. Revised relative potency values for PCDDs, PCDFs, and non-ortho-substituted PCBs for the optimized H4IIE-luc in vitro bioassay. Environmental Science and Pollution Research. Landsberg, Germany: Ecomed, 2013, roč. 20, č. 12, s. 8590-8599. ISSN 0944-1344. Dostupné z: https://dx.doi.org/10.1007/s11356-013-1770-2.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Revised relative potency values for PCDDs, PCDFs, and non-ortho-substituted PCBs for the optimized H4IIE-luc in vitro bioassay
Autoři LEE, K.T. (410 Korejská republika), S. HONG (410 Korejská republika), J.S. LEE (410 Korejská republika), K.H. CHUNG (410 Korejská republika), Klára HILSCHEROVÁ (203 Česká republika, domácí), J.P. GIESY (124 Kanada) a J.S. KHIM (410 Korejská republika, garant).
Vydání Environmental Science and Pollution Research, Landsberg, Germany, Ecomed, 2013, 0944-1344.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 30304 Public and environmental health
Stát vydavatele Německo
Utajení není předmětem státního či obchodního tajemství
Impakt faktor Impact factor: 2.757
Kód RIV RIV/00216224:14310/13:00071147
Organizační jednotka Přírodovědecká fakulta
Doi http://dx.doi.org/10.1007/s11356-013-1770-2
UT WoS 000327498600029
Klíčová slova anglicky Dioxin-like compounds; AhR activity; In vitro bioassay; Toxic equivalency factor; Relative potency
Štítky AKR, rivok
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Ing. Andrea Mikešková, učo 137293. Změněno: 9. 4. 2014 12:40.
Anotace
While the World Health Organization 2,3,7,8-tetrachlorodibenzo-p-dioxin (TCDD) equivalency factors are useful estimates of relative potencies of mixtures when conducting risk assessments, they are not useful when comparing the results of bioassays such as the H4IIE-luc to concentrations of TCDD equivalents calculated from instrumental analyses. Since there are thousands of dioxin-like compounds (DLCs), one use of screening assays is to determine if all of the aryl hydrocarbon receptor (AhR) active DLCs in a mixture have been accounted for in instrumental analyses. For this purpose, bioassay-specific relative potency (ReP) values are needed. RePs of 21 polychlorinated dibenzo-p-dioxins, polychlorinated dibenzofurans, and dioxin-like polychlorinated biphenyls that exhibit effects mediated through the AhR were determined by use of the H4IIE-luc assay. Different values of RePs are derived, depending on the statistical, curve-fitting methods used to derive them from the dose-response relationships. Here, we discuss the various methods for deriving RePs from in vitro data and their assumptions and effects on values of RePs. Full dose-response curves of 2,3,7,8-TCDD and other representative DLCs were used to estimate effective concentrations at multiple points (e.g., EC20-50-80), which were then used to estimate ReP of each DLC to 2,3,7,8-TCDD.
Návaznosti
ED0001/01/01, projekt VaVNázev: CETOCOEN
VytisknoutZobrazeno: 29. 5. 2024 20:04