TOMALOVÁ, Iva, Pavla FOLTYNOVÁ, Viktor KANICKÝ a Jan PREISLER. MALDI MS and ICP MS Detection of a Single CE Separation Record: A Tool for Metalloproteomics. Online. Analytical Chemistry. Washington: American Chemical Society, 2014, roč. 86, č. 1, s. 647-654. ISSN 0003-2700. Dostupné z: https://dx.doi.org/10.1021/ac402941e. [citováno 2024-04-24]
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název MALDI MS and ICP MS Detection of a Single CE Separation Record: A Tool for Metalloproteomics
Autoři TOMALOVÁ, Iva (203 Česká republika, domácí), Pavla FOLTYNOVÁ (203 Česká republika, domácí), Viktor KANICKÝ (203 Česká republika, domácí) a Jan PREISLER (203 Česká republika, garant, domácí)
Vydání Analytical Chemistry, Washington, American Chemical Society, 2014, 0003-2700.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 10406 Analytical chemistry
Stát vydavatele Spojené státy
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 5.636
Kód RIV RIV/00216224:14740/14:00073485
Organizační jednotka Středoevropský technologický institut
Doi http://dx.doi.org/10.1021/ac402941e
UT WoS 000329548700068
Klíčová slova anglicky MALDI MS; ICP MS; single run; capillary electrophoresis
Štítky kontrola MP, podil
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnil: prof. Mgr. Jan Preisler, Ph.D., učo 45329. Změněno: 15. 2. 2018 22:11.
Anotace
In this work, a novel approach based on off-line coupling of a single run of capillary electrophoresis (CE) separation to both matrix-assisted laser desorption/ionization (MALDI) and substrate-assisted laser desorption inductively coupled plasma (SALD ICP) mass spectrometry (MS) is presented. Using a liquid junction and subatmospheric deposition chamber, CE fractions were extracted from a separation capillary and collected as 20-nL droplets on a custom-built polyethylene terephthalate glycol (PETG) target plate coated with a 10-nm gold layer which guaranteed compatibility with both MALDI and SALD ICP techniques. The MALDI matrix solution was then added to the produced spots. After it was dried, the separation record was consecutively analyzed in MALDI MS and ICP MS instruments. Thus, both proteomic and metallomic information was obtained off-line from a single CE run. The concept was demonstrated by the analysis of a mixture of rabbit liver metallothionein isoforms. In an additional study, the droplets representing the archived separation record were alternately mixed with two different MALDI matrices to obtain complementary information on both the apoproteins and their complexes with metals from a single separation run. The presented technique is a viable alternative to online coupling of column separation to electrospray MS and nebulizer ICP MS.
Návaznosti
ED1.1.00/02.0068, projekt VaVNázev: CEITEC - central european institute of technology
EE2.3.30.0009, projekt VaVNázev: Zaměstnáním čerstvých absolventů doktorského studia k vědecké excelenci
GAP206/12/0538, projekt VaVNázev: Nové strategie úpravy vzorků pro desorpční hmotnostní spektrometrii
Investor: Grantová agentura ČR, Nové strategie úpravy vzorků pro desorpční hmotnostní spektrometrii
VytisknoutZobrazeno: 24. 4. 2024 10:07