2014
Outdoor passive air monitoring of semi volatile organic compounds (SVOCs): a critical evaluation of performance and limitations of polyurethane foam (PUF) disks
BOHLIN, Sara Pernilla; Ondřej AUDY; Lenka VAŇKOVÁ; Petr KUKUČKA; Petra PŘIBYLOVÁ et al.Základní údaje
Originální název
Outdoor passive air monitoring of semi volatile organic compounds (SVOCs): a critical evaluation of performance and limitations of polyurethane foam (PUF) disks
Autoři
BOHLIN, Sara Pernilla; Ondřej AUDY; Lenka VAŇKOVÁ; Petr KUKUČKA; Petra PŘIBYLOVÁ; Roman PROKEŠ; Šimon VOJTA a Jana KLÁNOVÁ
Vydání
ENVIRONMENTAL SCIENCE-PROCESSES & IMPACTS, CAMBRIDGE, ROYAL SOC CHEMISTRY, 2014, 2050-7887
Další údaje
Jazyk
angličtina
Typ výsledku
Článek v odborném periodiku
Obor
10511 Environmental sciences
Stát vydavatele
Velká Británie a Severní Irsko
Utajení
není předmětem státního či obchodního tajemství
Odkazy
Impakt faktor
Impact factor: 2.171
Označené pro přenos do RIV
Ano
Kód RIV
RIV/00216224:14310/14:00073271
Organizační jednotka
Přírodovědecká fakulta
UT WoS
EID Scopus
Klíčová slova anglicky
POLYCYCLIC AROMATIC-HYDROCARBONS; POLYBROMINATED DIPHENYL ETHERS; POLLUTANTS POPS; ORGANOCHLORINE PESTICIDES; POLYCHLORINATED-BIPHENYLS; AMBIENT AIR; INDUSTRIAL-AREAS; FLAME RETARDANTS; SAMPLING RATES; RURAL TRENDS
Příznaky
Mezinárodní význam, Recenzováno
Změněno: 31. 3. 2015 15:40, Ing. Andrea Mikešková
Anotace
V originále
The most commonly used passive air sampler (PAS) (i.e. polyurethane foam (PUF) disk) is cheap, versatile, and capable of accumulating compounds present both in gas and particle phases. Its performance for particle associated compounds is however disputable. In this study, twelve sets of triplicate PUF-PAS were deployed outdoors for exposure periods of 1-12 weeks together with continuously operated active samplers, to characterize sampling efficiency and derive sampling rates (R-S) for compounds belonging to 7 SVOC classes (including particle associated compounds). PUF-PAS efficiently and consistently sampled polychlorinated biphenyls (PCBs), organochlorine pesticides (OCPs), polycyclic aromatic hydrocarbons (PAHs), and eight novel brominated flame retardant (nBFR) compounds. Low accuracy and lack of sensitivity was observed for most polychlorinated dibenzo-p-dioxins/furans PCDD/Fs and polybrominated diphenyl ethers (PBDEs) (under the conditions of this study), with the exception of some congeners which may be used as qualitative markers for their respective classes. Application of compound specific R-S was found crucial for all compounds except PCBs. Sampling efficiency of the particle associated compounds was often low.
Návaznosti
| EE2.3.30.0009, projekt VaV |
| ||
| LH12074, projekt VaV |
| ||
| TB010MZP057, projekt VaV |
|