BERNARD, Vladan, Tomáš ANDRAŠINA, Vojtěch MORNSTEIN a Vlastimil VÁLEK. Radiofrequency tissue ablation inside of metal stent - A thermographis study. IRBM. New York: Elsevier Science INC., roč. 35, č. 3, s. 164-169. ISSN 1959-0318. doi:10.1016/j.irbm.2014.02.007. 2014.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Radiofrequency tissue ablation inside of metal stent - A thermographis study
Autoři BERNARD, Vladan (203 Česká republika, garant, domácí), Tomáš ANDRAŠINA (703 Slovensko, domácí), Vojtěch MORNSTEIN (203 Česká republika, domácí) a Vlastimil VÁLEK (203 Česká republika, domácí).
Vydání IRBM, New York, Elsevier Science INC. 2014, 1959-0318.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 10610 Biophysics
Stát vydavatele Spojené státy
Utajení není předmětem státního či obchodního tajemství
Impakt faktor Impact factor: 0.522
Kód RIV RIV/00216224:14110/14:00080134
Organizační jednotka Lékařská fakulta
Doi http://dx.doi.org/10.1016/j.irbm.2014.02.007
UT WoS 000339412400007
Klíčová slova anglicky article; biliary stent; controlled study; electrode; ex vivo study; experiment; human; infrared photography; radiofrequency ablation; surface property; temperature measurement; thermography
Štítky EL OK
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Soňa Böhmová, učo 232884. Změněno: 4. 9. 2014 13:30.
Anotace
Biliary stents are used to treat obstructions that occur in the bile ducts. The stents can be blocked by new tissue in a few months after their implanting. This complication can be solved by using radiofrequency ablation. The present article deals with monitoring of the process of monopolar thermoablation of a metal stent by using an infrared camera ex vivo. The metallic EGIS Biliary stents 10 mm × 80 mm were used in experiments; radiofrequency ablation due by catheter EndoHPB 8F at 460 kHz was used. The Flir B200 thermocamera was used for monitoring. The results show an increase in temperature of the stent's material during thermoablation process. It is believed that the metal stent becomes an active electrode. The results show an increase in temperature of the stent and the surrounding tissue during the treatment. Temperature distribution measured on stent was affected by power applied and obviously non-homogeneous. The maximum temperature values were observed at the ends of the stent. The temperature value of the stent during termoablation depended also on the position of the second (inactive) surface electrode. Results of this study have shown that there are many factors able to affect the final temperature or process of tissue ablation inside of the stent and around the stent. Infrared camera seems to be an appropriate instrument for observing the distribution and changes in temperature during ex vivo radiofrequency ablation.
Návaznosti
NT14586, projekt VaVNázev: Choledochoskopem navigovaná radiofrekvenční ablace žlučových cest.
Investor: Ministerstvo zdravotnictví ČR, Choledochoskopem navigovaná radiofrekvenční ablace žlučových cest.