2014
Simultaneous measurements of PSII activity and thallus temperature during linear cooling. A method to assess interspecific differences in photosynthetic processes in lichens from polar regions.
HÁJEK, Josef; Peter VÁCZI; Jana HAZDROVÁ a Miloš BARTÁKZákladní údaje
Originální název
Simultaneous measurements of PSII activity and thallus temperature during linear cooling. A method to assess interspecific differences in photosynthetic processes in lichens from polar regions.
Název česky
Souběžná měření aktivity PSII a teploty stélky během lineárního ochlazování. Metoda pro posouzení mezidruhových rozdílů ve fotosyntetických procesech lišejníků z polárních oblastí
Autoři
Vydání
Polar Ecology Conference, Ceske Budejovice, p. 56-57. 2014
Další údaje
Jazyk
angličtina
Typ výsledku
Konferenční abstrakt
Obor
10600 1.6 Biological sciences
Stát vydavatele
Česká republika
Utajení
není předmětem státního či obchodního tajemství
Označené pro přenos do RIV
Ano
Kód RIV
RIV/00216224:14310/14:00076590
Organizační jednotka
Přírodovědecká fakulta
ISBN
978-80-7394-463-6
Klíčová slova česky
odolnost proti zmražení; fluorescence chlorofylu; lišejníkový fotobiont; stélka; kritická teplota
Klíčová slova anglicky
cryoresistance; chlorophyll fluorescence; thallus; lichen photobiont; critical temperature
Změněno: 25. 9. 2014 11:25, prof. Ing. Miloš Barták, CSc.
V originále
A comparison of cryoresistance of isolated lichen photobiont and polar lichens is presented. Several species were chosen for this experiment: (1) algal cultures of Trebouxia glomerata, Trebouxia sp. (2) thalli of Usnea antarctica, Usnea aurantiaco-atra, Usnea longissima, Umbilicaria decussata, Umbilicaria cylindrica. All the samples were exposed to temperatures linearly decreasing from +20 °C to -40 °C under controlled conditions. During the experiment, sample temperature and two parameters of chlorophyll fluorescence – (1) potential (FV/FM) and (2) effective quantum yield of photochemical processes in photosystem II (YieldPSII) – were measured simultaneously. Cooling was provided by a KRYO 560-16 (PLANER, United Kingdom) device. For majority of samples, two cooling rates were used: 6 °C min-1 (fast) and 2 °C min-1 (slow) were used. The chlorophyll fluorescence was measured by a PC-linked PAM 2000 fluorometer (H. Walz, Germany). Measurements of YieldPSII were made every 30 s. For all samples, the response of FV/FM and YieldPSII to declining temperature showed an „S curve“ with critical temperatures, indicating high level of cryoresistance of the samples. In an individual sample, critical temperature for FV/FM was typically lower than for YieldPSII.
Česky
viz abstrakt v anglictine
Návaznosti
| LM2010009, projekt VaV |
|