2009
CytoPacq – On-line Framework for Simulating Fluorescence Microscopy Images
SVOBODA, David a Michal KOZUBEKZákladní údaje
Originální název
CytoPacq – On-line Framework for Simulating Fluorescence Microscopy Images
Autoři
SVOBODA, David (203 Česká republika, garant, domácí) a Michal KOZUBEK (203 Česká republika, domácí)
Vydání
Hands-on Image Processing, Robotiker-Tecnalia, Bilbao, Spain, 2009
Další údaje
Jazyk
angličtina
Typ výsledku
Vyžádané přednášky
Obor
20200 2.2 Electrical engineering, Electronic engineering, Information engineering
Stát vydavatele
Španělsko
Utajení
není předmětem státního či obchodního tajemství
Organizační jednotka
Fakulta informatiky
Klíčová slova anglicky
simulation; biomedical imaging; fluorescence microscopy; cell nucleus
Příznaky
Mezinárodní význam
Změněno: 6. 10. 2014 13:41, doc. RNDr. David Svoboda, Ph.D.
Anotace
V originále
In recent years, the biomedicine, like the other fields of research, has become more and more tied up with the computer science. The vast majority of measurements is acquired, stored and further evaluated using the instruments controlled by the appropriate computer hardware and software. In optical microscopy such an equipment has already become a standard. The whole process of observation can be typically split into four principal parts: 1. Specimen preparation, 2. Image transmission, 3. Image acquisition, 4. Image analysis. In the last step of this process a large variety of image processing methods is used. It is clear that the quality and correctness of results of such methods influence the final evaluation and conclusions. That is why each user has to verify whether the selected method is appropriate and whether it performs correctly. For this purpose, we implemented a simulation toolbox called CytoPacq (http://cbia.fi.muni.cz/simulator/) that is capable of simulating the first three steps: * 3D-CytoGen ... generates the digital phantom (specimen preparation) * 3D-OptiGen ... imitates the whole optical system (image transmission) * 3D-AcquiGen ... simulates the behavior of CCD camera (image acquisition) As a result, CytoPacq generates selected synthetic image data as they would look like if acquired by real microscope and camera. Furthermore, the ideal image of an unaffected specimen is also generated. Hence, the synthetic data can be submitted to any image analysis method and the results of such method can be simply compared to the ideal image and the quality can be evaluated. Currently, three types of objects can be generated (microspheres, nuclei of HL-60 cells, and nuclei of granulocytes). The generation of new types of phantoms (e.g. tissue clusters) is currently under development.
Návaznosti
LC535, projekt VaV |
| ||
2B06052, projekt VaV |
|