VOJTÍŠEK, Radovan, Jan MUŽÍK, Pavel ŠLAMPA, Marie BUDÍKOVÁ, Jaroslav HEJSEK, Petr SMOLÁK, Jiří FERDA a Jindřich FÍNEK. The impact of PET/CT scanning on the size of target volumes, radiation exposure of organs at risk, TCP and NTCP, in the radiotherapy planning of non-small cell lung cancer. Reports of Practical Oncology and Radiotherapy. Wroclaw: Elsevier Urban and Partner sp. z o.o., 2014, roč. 19, č. 3, s. 182-190. ISSN 1507-1367. Dostupné z: https://dx.doi.org/10.1016/j.rpor.2013.09.006.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název The impact of PET/CT scanning on the size of target volumes, radiation exposure of organs at risk, TCP and NTCP, in the radiotherapy planning of non-small cell lung cancer
Autoři VOJTÍŠEK, Radovan (203 Česká republika), Jan MUŽÍK (203 Česká republika), Pavel ŠLAMPA (203 Česká republika, garant, domácí), Marie BUDÍKOVÁ (203 Česká republika, domácí), Jaroslav HEJSEK (203 Česká republika), Petr SMOLÁK (203 Česká republika), Jiří FERDA (203 Česká republika) a Jindřich FÍNEK (203 Česká republika).
Vydání Reports of Practical Oncology and Radiotherapy, Wroclaw, Elsevier Urban and Partner sp. z o.o. 2014, 1507-1367.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 30200 3.2 Clinical medicine
Stát vydavatele Polsko
Utajení není předmětem státního či obchodního tajemství
Kód RIV RIV/00216224:14110/14:00077949
Organizační jednotka Lékařská fakulta
Doi http://dx.doi.org/10.1016/j.rpor.2013.09.006
UT WoS 000437602200005
Klíčová slova anglicky Non-small cell lung cancer; NTCP; PET/CT; Radiotherapy planning; TCP
Štítky EL OK, podil
Příznaky Recenzováno
Změnil Změnila: Soňa Böhmová, učo 232884. Změněno: 13. 1. 2015 09:24.
Anotace
Aim: To compare radiotherapy plans made according to CT and PET/CT and to investigate the impact of changes in target volumes on tumour control probability (TCP), normal tissue complication probability (NTCP) and the impact of PET/CT on the staging and treatment strategy. Background: Contemporary studies have proven that PET/CT attains higher sensitivity and specificity in the diagnosis of lung cancer and also leads to higher accuracy than CT alone in the process of target volume delineation in NSCLC. Materials and methods: Between October 2009 and March 2012, 31 patients with locally advanced NSCLC, who had been referred to radical radiotherapy were involved in our study. They all underwent planning PET/CT examination. Then we carried out two separate delineations of target volumes and two radiotherapy plans and we compared the following parameters of those plans: staging, treatment purpose, the size of GTV and PTV and the exposure of organs at risk (OAR). TCP and NTCP were also compared. Results: PET/CT information led to a significant decrease in the sizes of target volumes, which had the impact on the radiation exposure of OARs. The reduction of target volume sizes was not reflected in the significant increase of the TCP value. We found that there is a very strong direct linear relationship between all evaluated dosimetric parameters and NTCP values of all evaluated OARs. Conclusions: Our study found that the use of planning PET/CT in the radiotherapy planning of NSCLC has a crucial impact on the precise determination of target volumes, more precise staging of the disease and thus also on possible changes of treatment strategy.
VytisknoutZobrazeno: 26. 4. 2024 08:55