a 2014

3D CHEMICAL MAPPING OF SELECTED GEOLOGICAL SAMPLES USING COMBINATION OF LASER-INDUCED BREAKDOWN SPECTROSCOPY AND uCT

PROCHAZKA, David; Jindřich KYNICKÝ; Petra PROCHAZKOVÁ; Tomáš ZIKMUND; Jan NOVOTNÝ et al.

Základní údaje

Originální název

3D CHEMICAL MAPPING OF SELECTED GEOLOGICAL SAMPLES USING COMBINATION OF LASER-INDUCED BREAKDOWN SPECTROSCOPY AND uCT

Autoři

PROCHAZKA, David; Jindřich KYNICKÝ; Petra PROCHAZKOVÁ; Tomáš ZIKMUND; Jan NOVOTNÝ; Karel NOVOTNÝ; René KIZEK; Michal PETRILAK a Jozef KAISER

Vydání

European Symposium on Atomic Spectrometry ESAS 2014 & 15th Czech - Slovak Spectroscopic Conference, 2014. 2014

Další údaje

Jazyk

angličtina

Typ výsledku

Konferenční abstrakt

Obor

10406 Analytical chemistry

Stát vydavatele

Česká republika

Utajení

není předmětem státního či obchodního tajemství

Odkazy

Označené pro přenos do RIV

Ano

Kód RIV

RIV/00216224:14740/14:00078550

Organizační jednotka

Středoevropský technologický institut

ISBN

978-80-905704-1-2

Klíčová slova anglicky

LIBS; Mapping; Geological samples
Změněno: 16. 3. 2015 09:20, doc. Mgr. Karel Novotný, Ph.D.

Anotace

V originále

In this paper it is described quasi-nondestructive 3D chemical mapping of minerals using combination of information from uCT, Tescan Integrated Mineral analyzer (TIMA) and Laser-induced breakdown spectroscopy (LIBS) measurements. The described results bring information about spatial deposition and volume of selected minerals within the volume of the sample and partially from the surface. The main point of suggested approach is to assign the different densities from the tomogram to the different elements and minerals respectively from the chemical maps obtained via LIBS on the sample surface. In order to achieve best possible spatial resolution and plasma intensity double pulse LIBS (DP LIBS) was utilized. The spot size was assessed on 50 um via optical profilometer (MicroProf 100, FRT) and in respect to this size the spatial resolution was selected on 100 um in both directions. As another approach for obtaining chemical maps was selected Tescan Integrated mineral analyzer (TIMA) which is special device developed for mineral analysis. The spatial deposition of minerals and corresponding elements was compared from both techniques with very good results. Moreover, it was shown the advantage of LIBS, when the chemical map was prepared on the sample with no pretreatment.

Návaznosti

ED1.1.00/02.0068, projekt VaV
Název: CEITEC - central european institute of technology