MOUDR, Jiří, Jana SVAČINOVÁ, Eva ZÁVODNÁ a Nataša HONZÍKOVÁ. The Vibration Plethysmographic Method of Arterial Compliance Analysis in Dependence on Transmural Pressure. Physiological Research. Praha: Fyziologický ústav AV ČR, 2014, roč. 63, Suppl 4, s. "S489"-"S495", 7 s. ISSN 0862-8408.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název The Vibration Plethysmographic Method of Arterial Compliance Analysis in Dependence on Transmural Pressure
Autoři MOUDR, Jiří (203 Česká republika, domácí), Jana SVAČINOVÁ (203 Česká republika, domácí), Eva ZÁVODNÁ (203 Česká republika, garant, domácí) a Nataša HONZÍKOVÁ (203 Česká republika, domácí).
Vydání Physiological Research, Praha, Fyziologický ústav AV ČR, 2014, 0862-8408.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 30105 Physiology
Stát vydavatele Česká republika
Utajení není předmětem státního či obchodního tajemství
Impakt faktor Impact factor: 1.293
Kód RIV RIV/00216224:14110/14:00079032
Organizační jednotka Lékařská fakulta
UT WoS 000351014100006
Klíčová slova anglicky Arterial compliance; Finger arterial pressure; Plethysmography; Transmural arterial pressure; Frequency characteristic
Štítky EL OK
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Ing. Mgr. Věra Pospíšilíková, učo 9005. Změněno: 24. 4. 2015 13:25.
Anotace
The aim of this study was to obtain a detailed analysis of the relationship between the finger arterial compliance C [ml/mm Hg] and the arterial transmural pressure Pt [mm Hg]. We constructed a dynamic plethysmograph enabling us to set up a constant pressure P^ [mm Hg] and a superimposed fast pressure vibration in the finger cuff (equipped with a source of infra-red light and a photoelectric sensor for the measurement of arterial volume). Pcss could be set on the required time interval in steps ranging between 30 and 170 mm Hg, and on sinusoidal pressure oscillation with an amplitude Pca (2 mmHg) and a frequency f (20, 25, 30, 35, 40 Hz). At the same time continuous blood pressure BP was measured on the adjacent finger (Portapres). We described the volume dependence of a unitary arterial length on the time-varying transmural pressure acting on the arterial wall (externally Pcss+Pca.sin(2nO, internally BP) by a second-order differential equation for volume. This equation was linearized within a small range of selected BP. In the next step, a Fourier transform was applied to obtain the frequency characteristic in analytic form of a complex linear combination of frequency functions. While series of oscillations [Pca, f] were applied for each Pcss, the corresponding response of the plethysmogram was measured. Amplitude spectra were obtained to estimate coefficients of the frequency characteristic by regression analysis. We determined the absolute value: elastance E, and its inverse value: compliance (C=1/E). Then, C=C(Pt) was acquired by applying sequences of oscillations for different P^ (and thus Pt) by the above-described procedure. This methodology will be used for the study of finger arterial compliance in different physiological and pathological conditions.
Návaznosti
MUNI/A/0957/2013, interní kód MUNázev: Studium kardiovaskulárních regulací ve zdraví i nemoci (Akronym: SKAREZNEM)
Investor: Masarykova univerzita, Studium kardiovaskulárních regulací ve zdraví i nemoci, DO R. 2020_Kategorie A - Specifický výzkum - Studentské výzkumné projekty
VytisknoutZobrazeno: 27. 7. 2024 14:13