HNYLUCHOVÁ, Zuzana, Petra BJALONČÍKOVÁ, Pavel KARAS, Filip MRAVEC, Tereza HALÁSOVÁ, Miloslav PEKAŘ, Lukáš KUBALA a Jan VÍTEČEK. A simple microviscometric approach based on Brownian motion tracking. Review of Scientific Instruments. Melville, USA: American Institute of Physics, 2015, roč. 86, č. 2, s. 1-5. ISSN 0034-6748. Dostupné z: https://dx.doi.org/10.1063/1.4913386.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název A simple microviscometric approach based on Brownian motion tracking
Autoři HNYLUCHOVÁ, Zuzana (203 Česká republika, garant), Petra BJALONČÍKOVÁ (203 Česká republika), Pavel KARAS (203 Česká republika, domácí), Filip MRAVEC (203 Česká republika), Tereza HALÁSOVÁ (203 Česká republika), Miloslav PEKAŘ (203 Česká republika), Lukáš KUBALA (203 Česká republika) a Jan VÍTEČEK (203 Česká republika).
Vydání Review of Scientific Instruments, Melville, USA, American Institute of Physics, 2015, 0034-6748.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 10610 Biophysics
Stát vydavatele Spojené státy
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 1.336
Kód RIV RIV/00216224:14330/15:00082430
Organizační jednotka Fakulta informatiky
Doi http://dx.doi.org/10.1063/1.4913386
UT WoS 000350552700039
Klíčová slova anglicky Viscosity; Brownian motion; Computer software; Diffusion; Particle trajectory
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnil: RNDr. Pavel Šmerk, Ph.D., učo 3880. Změněno: 25. 5. 2017 06:14.
Anotace
Viscosity—an integral property of a liquid—is traditionally determined by mechanical instruments. The most pronounced disadvantage of such an approach is the requirement of a large sample volume, which poses a serious obstacle, particularly in biology and biophysics when working with limited samples. Scaling down the required volume by means of microviscometry based on tracking the Brownian motion of particles can provide a reasonable alternative. In this paper, we report a simple microviscometric approach which can be conducted with common laboratory equipment. The core of this approach consists in a freely available standalone script to process particle trajectory data based on a Newtonian model. In our study, this setup allowed the sample to be scaled down to 10 ul. The utility of the approach was demonstrated using model solutions of glycerine, hyaluronate, and mouse blood plasma. Therefore, this microviscometric approach based on a newly developed freely available script can be suggested for determination of the viscosity of small biological samples (e.g., body fluids).
VytisknoutZobrazeno: 12. 10. 2024 08:33