Possibilities and analytical properties of the radiofrequency plasma pencil operating in the continuous and in the pulsed mode

NOVOSÁD, Lukáš; Aleš HRDLIČKA; Pavel SLAVÍČEK; Vítězslav OTRUBA; Viktor KANICKÝ et al.

Základní údaje

Originální název

Possibilities and analytical properties of the radiofrequency plasma pencil operating in the continuous and in the pulsed mode

Název česky

Možnosti a analytické vlastnosti plazmové tužky provozované v kontinuálním a pulzním módu

Autoři

NOVOSÁD, Lukáš; Aleš HRDLIČKA; Pavel SLAVÍČEK; Vítězslav OTRUBA a Viktor KANICKÝ

Vydání

Journal of analytical atomic spectrometry, Cambridge, Royal Society of Chemistry, 2015, 0267-9477

Další údaje

Jazyk

angličtina

Typ výsledku

Článek v odborném periodiku

Obor

10406 Analytical chemistry

Stát vydavatele

Velká Británie a Severní Irsko

Utajení

není předmětem státního či obchodního tajemství

Impakt faktor

Impact factor: 3.379

Označené pro přenos do RIV

Ano

Kód RIV

RIV/00216224:14740/15:00082606

Organizační jednotka

Středoevropský technologický institut

EID Scopus

Klíčová slova česky

plazmová tužka; výboj; koncentrace; intenzita; pulzní; kontinuální; mód; analýza; vzorek;

Klíčová slova anglicky

plasma pencil; discharge; concentration; intensity; pulsed; continuous; mode; analysis; sample;

Štítky

Příznaky

Mezinárodní význam, Recenzováno
Změněno: 23. 3. 2016 09:18, Mgr. Eva Špillingová

Anotace

V originále

A two-electrode capacitively coupled plasma jet discharge operating at a 13.56 MHz symmetrical sinusoidal frequency carrier wave in a continuous mode and in a pulsed mode is described in this paper. The Internally pulsed mode was realised by the frequency modulation using a symmetrical rectangular frequency of 22 kHz with a duty cycle of 90%. The pulsed mode has an effect on the electron number densities ranging from 1 x 10(14) to 1.2 x 10(15) in the pulsed mode and from 1.7 x 10(14) to 1.0 x 10(15) cm(-3) in the continuous mode, gas temperatures 670-950 K in the pulsed and 630-880 K in the continuous mode, excitation temperatures 3100-4250 K in the pulsed and 3500-4280 K in the continuous mode, slopes and intercepts of the calibration lines and limits of detection and a weak effect on the coefficients of determination. All these parameters were measured at three different positions from the sample inlet of the plasma pencil. Most line intensities and the excitation temperature decreased while calcium lines and gas temperature calculated from OH radicals increased in the pulsed mode. These results indicate a strong interaction between calcium species and OH radicals. Analysis of real low mineralized water samples showed similarity of the yielded results to those obtained by reference ICP-OES.