NOVOSÁD, Lukáš, Aleš HRDLIČKA, Pavel SLAVÍČEK, Vítězslav OTRUBA a Viktor KANICKÝ. Possibilities and analytical properties of the radiofrequency plasma pencil operating in the continuous and in the pulsed mode. Journal of analytical atomic spectrometry. Cambridge: Royal Society of Chemistry, 2015, roč. 30, č. 2, s. 459-467. ISSN 0267-9477. Dostupné z: https://dx.doi.org/10.1039/c4ja00402g.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Possibilities and analytical properties of the radiofrequency plasma pencil operating in the continuous and in the pulsed mode
Název česky Možnosti a analytické vlastnosti plazmové tužky provozované v kontinuálním a pulzním módu
Autoři NOVOSÁD, Lukáš (203 Česká republika, domácí), Aleš HRDLIČKA (203 Česká republika, garant, domácí), Pavel SLAVÍČEK (203 Česká republika, domácí), Vítězslav OTRUBA (203 Česká republika, domácí) a Viktor KANICKÝ (203 Česká republika, domácí).
Vydání Journal of analytical atomic spectrometry, Cambridge, Royal Society of Chemistry, 2015, 0267-9477.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 10406 Analytical chemistry
Stát vydavatele Velká Británie a Severní Irsko
Utajení není předmětem státního či obchodního tajemství
WWW odkaz na článek
Impakt faktor Impact factor: 3.379
Kód RIV RIV/00216224:14740/15:00082606
Organizační jednotka Středoevropský technologický institut
Doi http://dx.doi.org/10.1039/c4ja00402g
UT WoS 000349145700018
Klíčová slova česky plazmová tužka; výboj; koncentrace; intenzita; pulzní; kontinuální; mód; analýza; vzorek;
Klíčová slova anglicky plasma pencil; discharge; concentration; intensity; pulsed; continuous; mode; analysis; sample;
Štítky podil, rivok
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Mgr. Eva Špillingová, učo 110713. Změněno: 23. 3. 2016 09:18.
Anotace
A two-electrode capacitively coupled plasma jet discharge operating at a 13.56 MHz symmetrical sinusoidal frequency carrier wave in a continuous mode and in a pulsed mode is described in this paper. The Internally pulsed mode was realised by the frequency modulation using a symmetrical rectangular frequency of 22 kHz with a duty cycle of 90%. The pulsed mode has an effect on the electron number densities ranging from 1 x 10(14) to 1.2 x 10(15) in the pulsed mode and from 1.7 x 10(14) to 1.0 x 10(15) cm(-3) in the continuous mode, gas temperatures 670-950 K in the pulsed and 630-880 K in the continuous mode, excitation temperatures 3100-4250 K in the pulsed and 3500-4280 K in the continuous mode, slopes and intercepts of the calibration lines and limits of detection and a weak effect on the coefficients of determination. All these parameters were measured at three different positions from the sample inlet of the plasma pencil. Most line intensities and the excitation temperature decreased while calcium lines and gas temperature calculated from OH radicals increased in the pulsed mode. These results indicate a strong interaction between calcium species and OH radicals. Analysis of real low mineralized water samples showed similarity of the yielded results to those obtained by reference ICP-OES.
Návaznosti
ED1.1.00/02.0068, projekt VaVNázev: CEITEC - central european institute of technology
ED2.1.00/03.0086, projekt VaVNázev: Regionální VaV centrum pro nízkonákladové plazmové a nanotechnologické povrchové úpravy
VytisknoutZobrazeno: 21. 9. 2024 03:35