J 2015

Sensitive determination of glutathione in biological samples by capillary electrophoresis with green (515 nm) laser-induced fluorescence detection

HODÁKOVÁ, Júlia; Jan PREISLER; František FORET a Petr KUBÁŇ

Základní údaje

Originální název

Sensitive determination of glutathione in biological samples by capillary electrophoresis with green (515 nm) laser-induced fluorescence detection

Autoři

Vydání

Journal of Chromatography A, AMSTERDAM, Elsevier, 2015, 0021-9673

Další údaje

Jazyk

angličtina

Typ výsledku

Článek v odborném periodiku

Obor

10406 Analytical chemistry

Stát vydavatele

Nizozemské království

Utajení

není předmětem státního či obchodního tajemství

Impakt faktor

Impact factor: 3.926

Označené pro přenos do RIV

Ano

Kód RIV

RIV/00216224:14310/15:00080903

Organizační jednotka

Přírodovědecká fakulta

EID Scopus

Klíčová slova anglicky

Capillary electrophoresis; Laser-induced fluorescence; Glutathione; Eosin-5-maleimide

Štítky

Příznaky

Mezinárodní význam, Recenzováno
Změněno: 15. 2. 2018 22:06, prof. Mgr. Jan Preisler, Ph.D.

Anotace

V originále

A new sensitive capillary electrophoretic method with laser-induced fluorescence (LIF) was developed for quantitation of glutathione (GSH) in biological samples. Eosin-5-maleimide was used to label the GSH molecule and the formed conjugate was separated in a 15 mM 4-(2-hydroxyethyl)-1-piperazineethanesulfonic acid electrolyte at pH 7.0 in less than 3 min. The conjugate was detected with an in-house built LIF system, utilizing an inexpensive 515 nm diode laser module. Studies were performed to optimize the derivatizatiory(the ratio of reagent to analyte, the reaction time, pH, etc.) and separation conditions. Sensitive detection of GSH at concentrations as low as 0.18 nM was obtained. The method was applied in the analysis of biological fluids (exhaled breath condensate, saliva) and was found to be suitable for determination of GSH in these samples at trace levels below 1 nM. To the best of our knowledge, this is the first report on determination of GSH in exhaled breath condensate by capillary electrophoresis (CE). (C) 2015 Elsevier B.V. All rights reserved.

Návaznosti

ED1.1.00/02.0068, projekt VaV
Název: CEITEC - central european institute of technology
GA13-21919S, projekt VaV
Název: Vývoj neinvazivních metod odběru vzorků a analýzy v point-of-care dignostice biologických materiálů.
Investor: Grantová agentura ČR, Vývoj neinvazivních metod odberu vzorku a analýzy v point-of-care dignostice biologických materiálu