VANEK, Tomas, Martin HALECKY, Jan PÁCA, Lubos ZAPOTOCKY, Tereza GELBÍČOVÁ, Renata VADKERTIOVA, Evguenii KOZLIAK a Kim JONES. A two-stage combined trickle bed reactor/biofilter for treatment of styrene/acetone vapor mixtures. Journal of Environmental Science and Health Part A Toxic/Hazardous Substances & Environmental Engineering. 2015, roč. 50, č. 11, s. 1148-1159. ISSN 1093-4529. Dostupné z: https://dx.doi.org/10.1080/10934529.2015.1047672.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název A two-stage combined trickle bed reactor/biofilter for treatment of styrene/acetone vapor mixtures
Autoři VANEK, Tomas (203 Česká republika), Martin HALECKY (203 Česká republika), Jan PÁCA (203 Česká republika, garant), Lubos ZAPOTOCKY (203 Česká republika), Tereza GELBÍČOVÁ (203 Česká republika, domácí), Renata VADKERTIOVA (703 Slovensko), Evguenii KOZLIAK (840 Spojené státy) a Kim JONES (840 Spojené státy).
Vydání Journal of Environmental Science and Health Part A Toxic/Hazardous Substances & Environmental Engineering, 2015, 1093-4529.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor Biotechnologie a bionika
Stát vydavatele Spojené státy
Utajení není předmětem státního či obchodního tajemství
Impakt faktor Impact factor: 1.276
Kód RIV RIV/00216224:14310/15:00083573
Organizační jednotka Přírodovědecká fakulta
Doi http://dx.doi.org/10.1080/10934529.2015.1047672
UT WoS 000359339900007
Klíčová slova anglicky acetone; biofiltration; biofilm identification; intermediates; styrene; two-stage reactor
Štítky AKR, rivok
Změnil Změnila: Ing. Andrea Mikešková, učo 137293. Změněno: 24. 3. 2016 14:38.
Anotace
Performance of a two-stage biofiltration system was investigated for removal of styrene-acetone mixtures. High steady-state acetone loadings resulted in a significant inhibition of the system’s performance in both acetone and styrene removal. This inhibition was shown to result from the acetone accumulation within the upstream trickle-bed bioreactor (TBR) circulating mineral medium, which was observed by direct chromatographic measurements. Placing a biofilter (BF) downstream to this TBR overcomes the inhibition as long as the biofilter has a sufficient bed height. A different kind of inhibition of styrene biodegradation was observed within the biofilter at very high acetone loadings. In addition to steady-state measurements, dynamic tests confirmed that the reactor overloading can be readily overcome, once the accumulated acetone in the TBR fluids is degraded. No sizable metabolite accumulation in the medium was observed for either TBR or BF. Analyses of the biodegradation activities of microbial isolates from the biofilm corroborated the trends observed for the two-stage biofiltration system, particularly the occurrence of an inhibition threshold by excess acetone.
VytisknoutZobrazeno: 8. 5. 2024 12:25