HEGER, Zbynek, Natalia CERNEI, Sona KRIZKOVA, Michal MASAŘÍK, Pavel KOPEL, Petr HODEK, Ondrej ZITKA, Vojtech ADAM a Rene KIZEK. Paramagnetic Nanoparticles as a Platform for FRET-Based Sarcosine Picomolar Detection. Scientific Reports. London: Nature Publishing Group, 2015, roč. 5, "8868", s. 1-7. ISSN 2045-2322. Dostupné z: https://dx.doi.org/10.1038/srep08868.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Paramagnetic Nanoparticles as a Platform for FRET-Based Sarcosine Picomolar Detection
Autoři HEGER, Zbynek (203 Česká republika), Natalia CERNEI (203 Česká republika), Sona KRIZKOVA (203 Česká republika), Michal MASAŘÍK (203 Česká republika, garant, domácí), Pavel KOPEL (203 Česká republika), Petr HODEK (203 Česká republika), Ondrej ZITKA (203 Česká republika), Vojtech ADAM (203 Česká republika) a Rene KIZEK (203 Česká republika).
Vydání Scientific Reports, London, Nature Publishing Group, 2015, 2045-2322.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 30105 Physiology
Stát vydavatele Velká Británie a Severní Irsko
Utajení není předmětem státního či obchodního tajemství
Impakt faktor Impact factor: 5.228
Kód RIV RIV/00216224:14110/15:00083933
Organizační jednotka Lékařská fakulta
Doi http://dx.doi.org/10.1038/srep08868
UT WoS 000350549200018
Klíčová slova anglicky Prostate-cancer progression; Urine samples; Diagnostics; Carcinoma
Štítky EL OK
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Soňa Böhmová, učo 232884. Změněno: 22. 9. 2015 14:38.
Anotace
Herein, we describe an ultrasensitive specific biosensing system for detection of sarcosine as a potential biomarker of prostate carcinoma based on Forster resonance energy transfer (FRET). The FRET biosensor employs anti-sarcosine antibodies immobilized on paramagnetic nanoparticles surface for specific antigen binding. Successful binding of sarcosine leads to assembly of a sandwich construct composed of anti-sarcosine antibodies keeping the Forster distance (Ro) of FRET pair in required proximity. The detection is based on spectral overlap between gold-functionalized green fluorescent protein and antibodies@quantum dots bioconjugate (lambda(ex) 400 nm). The saturation curve of sarcosine based on FRET efficiency (F-604/F-510 ratio) was tested within linear dynamic range from 5 to 50 nM with detection limit down to 50 pM. Assembled biosensor was then successfully employed for sarcosine quantification in prostatic cell lines (PC3, 22Rv1, PNT1A), and urinary samples of prostate adenocarcinoma patients.
Návaznosti
ED1.1.00/02.0068, projekt VaVNázev: CEITEC - central european institute of technology
VytisknoutZobrazeno: 27. 7. 2024 14:36