VESELÝ, Petr. Contribution of sVEP visual acuity testing in comparison with subjective visual acuity. Biomedical Papers. Olomouc: Palacký University, 2015, roč. 159, č. 4, s. 616-621. ISSN 1213-8118. Dostupné z: https://dx.doi.org/10.5507/bp.2015.002.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Contribution of sVEP visual acuity testing in comparison with subjective visual acuity
Autoři VESELÝ, Petr (203 Česká republika, garant, domácí).
Vydání Biomedical Papers, Olomouc, Palacký University, 2015, 1213-8118.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 30200 3.2 Clinical medicine
Stát vydavatele Česká republika
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 0.924
Kód RIV RIV/00216224:14110/15:00085194
Organizační jednotka Lékařská fakulta
Doi http://dx.doi.org/10.5507/bp.2015.002
UT WoS 000366566700016
Klíčová slova anglicky visual acuity electrophysiological methods visual evoked potentials Snellen chart ETDRS chart
Štítky EL OK
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Soňa Böhmová, učo 232884. Změněno: 28. 4. 2016 14:33.
Anotace
Aims: Visual acuity determination is an important task in ophthalmology and optometry practices. Visual acuity can be examined objectively or subjectively. The objective examination method, sVEP, allows for quick objective measurements of patient's visual acuity. Previous studies have not demonstrated the repeatability of this objective sVEP method. This study aims to evaluate the sVEP method and compare it to a subjective method. Methods and Results: The sample was divided into two groups. For the first group, visual acuity was measured with sVEP and Snellen methods on only one patient twelve times. In the second group, visual acuity was measured twice with sVEP followed twice with the Snellen method with Landolt's rings and logMAR modification on 32 non-pathological patients. Results showed significant differences between average values of visual acuity obtained with both methods (sVEP and Snellen) in both samples (T-test, P < 0.01; Wilcoxon test, P = 0.02 in second group). In the second group, significant correlations between repeated sVEP measurements (Spearman test, P < 0.05, r = 0.69) were found but no significant correlation between average sVEP measurement and average Snellen measurement (Spearman test, P > 0.05, r = 0.15) was found. Conclusion: Objective measurement of visual acuity with sVEP is a valid and reliable method, but is recommended only when it is not possible to use a subjective method for measuring visual acuity, e.g. children, patients with mental retardation or simulating/dissimulating patients.
Návaznosti
MUNI/A/0886/2012, interní kód MUNázev: Využití elektrofyziologických metod pro hodnocení zrakové ostrosti (Akronym: sVEP)
Investor: Masarykova univerzita, Využití elektrofyziologických metod pro hodnocení zrakové ostrosti, DO R. 2020_Kategorie A - Specifický výzkum - Studentské výzkumné projekty
VytisknoutZobrazeno: 27. 4. 2024 05:19