JUŘÍK, Tomáš, Pavel PODEŠVA, Zdeněk FARKA, David KOVÁŘ, Petr SKLÁDAL a František FORET. Nanostructured gold deposited in gelatin template applied for electrochemical assay of glucose in serum. Electrochimica Acta. Oxford: Pergamon-Elsevier, 2016, roč. 188, January, s. 277-285. ISSN 0013-4686. Dostupné z: https://dx.doi.org/10.1016/j.electacta.2015.12.009.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Nanostructured gold deposited in gelatin template applied for electrochemical assay of glucose in serum
Autoři JUŘÍK, Tomáš (203 Česká republika, domácí), Pavel PODEŠVA (203 Česká republika), Zdeněk FARKA (203 Česká republika, domácí), David KOVÁŘ (203 Česká republika, domácí), Petr SKLÁDAL (203 Česká republika, garant, domácí) a František FORET (203 Česká republika, domácí).
Vydání Electrochimica Acta, Oxford, Pergamon-Elsevier, 2016, 0013-4686.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 10600 1.6 Biological sciences
Stát vydavatele Velká Británie a Severní Irsko
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 4.798
Kód RIV RIV/00216224:14740/16:00089213
Organizační jednotka Středoevropský technologický institut
Doi http://dx.doi.org/10.1016/j.electacta.2015.12.009
UT WoS 000370986500032
Klíčová slova anglicky Gold nanostructures; Gelatin template; Glucose electrooxidation; Non-enzymatic sensor; Blood analysis
Štítky rivok
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnil: doc. Mgr. Zdeněk Farka, Ph.D., učo 357740. Změněno: 28. 9. 2017 11:03.
Anotace
Gelatin-templated gold nanostructures were fabricated in order to improve the sensitivity of non-enzymatic determination of glucose. The three-dimensional cavities were created by crosslinking of gelatin layer on the electrode and the specific saw tooth-like morphology of surface was formed by electrodeposition of gold through the cavities. Scanning electron microscopy (SEM) and atomic force microscopy (AFM) were used for the investigation of nanostructure growth and characterization of prepared surfaces. Glucose was detected by a direct electrochemical oxidation during cyclic voltammetry in alkaline solution with excellent sensitivity of 1165 uA mM-1 cm-2, wide linear range from 32 uM to 10 mM and limit of detection (LOD) of 90 uM. During amperometric measurements LOD of 1.5 uM was achieved. The sensor was able to detect real concentrations of glucose in deproteinized human serum with negligible interference of oxidizable blood components. Great correlation with results obtained from reference methods (commercial glucometer and standard kit for photometric glucose detection) was demonstrated; the determination of glucose in serum was performed with relative standard deviation of 4%. The sensor exhibits a strong potential as a rapid and sensitive non-enzymatic approach in future applications for clinical analyses.
Návaznosti
ED1.1.00/02.0068, projekt VaVNázev: CEITEC - central european institute of technology
VytisknoutZobrazeno: 14. 5. 2024 03:50