A Thermographic Comparison of Irreversible Electroporation and Radiofrequency Ablation
BERNARD, Vladan, Tomáš ANDRAŠINA, D. ČERVINKA, J. MARTIŠ, P. PROCHÁZKA et. al.Základní údaje
Originální název
A Thermographic Comparison of Irreversible Electroporation and Radiofrequency Ablation
Název česky
Termografické srovnání radiofrekvenční ablace a irreverzibilní elektroporace
Autoři
BERNARD, Vladan (203 Česká republika, garant, domácí), Tomáš ANDRAŠINA (703 Slovensko), D. ČERVINKA (203 Česká republika), J. MARTIŠ (203 Česká republika), P. PROCHÁZKA (203 Česká republika), Vojtěch MORNSTEIN (203 Česká republika, domácí) a Vlastimil VÁLEK (203 Česká republika)
Vydání
IRBM, New York, Elsevier Science INC. 2017, 1959-0318
Další údaje
Jazyk
angličtina
Typ výsledku
Článek v odborném periodiku
Obor
20601 Medical engineering
Stát vydavatele
Spojené státy
Utajení
není předmětem státního či obchodního tajemství
Impakt faktor
Impact factor: 0.897
Kód RIV
RIV/00216224:14110/17:00095628
Organizační jednotka
Lékařská fakulta
UT WoS
000398761500004
Klíčová slova anglicky
Balloon catheter; Heating effect; Infrared camera; Irreversible electroporation; Radiofrequency ablation; Temperature
Štítky
Příznaky
Mezinárodní význam, Recenzováno
Změněno: 15. 3. 2018 17:20, Soňa Böhmová
Anotace
V originále
Radiofrequency ablation and irreversible electroporation are both interventional procedures used in treating cancer diseases generally and may be used in treatment of liver cancer. The two differ in terms of their action and thermal effects. The present study examined thermal effects of radiofrequency ablation and modified irreversible electroporation ex vivo in porcine liver. Standard radiofrequency ablation was used during the experiments, as was a unique, experimental high-voltage generator of the research team's own construction coupled with a newly designed balloon electrode catheter for irreversible electroporation. The tested balloon catheter was newly designed for application in the biliary tract. The temperature of porcine liver tissue was monitored without contact by infrared camera. The results show significantly different temperature of tissue around electrodes for radiofrequency ablation and irreversible electroporation. The data obtained from radiofrequency ablation with maximum tested output power of 10 watts show a symmetrical area of tissue near active electrodes with temperature increased by more than 30 C. Irreversible electroporation methods showed temperature increasing approximately by 5 C. To summarize, the thermal research showed that the difference between standard RFA and innovated IRE with the balloon catheter lies not just in the differing mechanism of action, as is well known, but also in its thermal effects. There was documented that tissue temperature was much higher for RFA than for IRE, particularly for the maximum tested output parameters. The applicability of the newly designed balloon catheters was confirmed.
Návaznosti
NV15-32484A, projekt VaV |
|