BERNARD, Vladan, Tomáš ANDRAŠINA, D. ČERVINKA, J. MARTIŠ, P. PROCHÁZKA, Vojtěch MORNSTEIN a Vlastimil VÁLEK. A Thermographic Comparison of Irreversible Electroporation and Radiofrequency Ablation. Online. IRBM. New York: Elsevier Science INC., 2017, roč. 38, č. 1, s. 26-33. ISSN 1959-0318. Dostupné z: https://dx.doi.org/10.1016/j.irbm.2016.11.001. [citováno 2024-04-23]
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název A Thermographic Comparison of Irreversible Electroporation and Radiofrequency Ablation
Název česky Termografické srovnání radiofrekvenční ablace a irreverzibilní elektroporace
Autoři BERNARD, Vladan (203 Česká republika, garant, domácí), Tomáš ANDRAŠINA (703 Slovensko), D. ČERVINKA (203 Česká republika), J. MARTIŠ (203 Česká republika), P. PROCHÁZKA (203 Česká republika), Vojtěch MORNSTEIN (203 Česká republika, domácí) a Vlastimil VÁLEK (203 Česká republika)
Vydání IRBM, New York, Elsevier Science INC. 2017, 1959-0318.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 20601 Medical engineering
Stát vydavatele Spojené státy
Utajení není předmětem státního či obchodního tajemství
Impakt faktor Impact factor: 0.897
Kód RIV RIV/00216224:14110/17:00095628
Organizační jednotka Lékařská fakulta
Doi http://dx.doi.org/10.1016/j.irbm.2016.11.001
UT WoS 000398761500004
Klíčová slova anglicky Balloon catheter; Heating effect; Infrared camera; Irreversible electroporation; Radiofrequency ablation; Temperature
Štítky EL OK
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Soňa Böhmová, učo 232884. Změněno: 15. 3. 2018 17:20.
Anotace
Radiofrequency ablation and irreversible electroporation are both interventional procedures used in treating cancer diseases generally and may be used in treatment of liver cancer. The two differ in terms of their action and thermal effects. The present study examined thermal effects of radiofrequency ablation and modified irreversible electroporation ex vivo in porcine liver. Standard radiofrequency ablation was used during the experiments, as was a unique, experimental high-voltage generator of the research team's own construction coupled with a newly designed balloon electrode catheter for irreversible electroporation. The tested balloon catheter was newly designed for application in the biliary tract. The temperature of porcine liver tissue was monitored without contact by infrared camera. The results show significantly different temperature of tissue around electrodes for radiofrequency ablation and irreversible electroporation. The data obtained from radiofrequency ablation with maximum tested output power of 10 watts show a symmetrical area of tissue near active electrodes with temperature increased by more than 30 C. Irreversible electroporation methods showed temperature increasing approximately by 5 C. To summarize, the thermal research showed that the difference between standard RFA and innovated IRE with the balloon catheter lies not just in the differing mechanism of action, as is well known, but also in its thermal effects. There was documented that tissue temperature was much higher for RFA than for IRE, particularly for the maximum tested output parameters. The applicability of the newly designed balloon catheters was confirmed.
Návaznosti
NV15-32484A, projekt VaVNázev: Využití nových biotechnologií v prevenci a léčbě stenóz žlučových cest
VytisknoutZobrazeno: 23. 4. 2024 19:43