HEJC, Jakub, Oto JANOUSEK, Marina RONZHINA, Tibor STRAČINA, Veronika OLEJNÍČKOVÁ, Jana KOLAROVA a Marie NOVÁKOVÁ. Response of Ventricular Repolarization Parameters to Preload Changes in the Isolated Working Heart. In Alan Murray. Computing in Cardiology 2016. Washington: IEEE Computer Society, 2017, s. 409-412. ISBN 978-1-5090-0896-4.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Response of Ventricular Repolarization Parameters to Preload Changes in the Isolated Working Heart
Autoři HEJC, Jakub (203 Česká republika), Oto JANOUSEK (203 Česká republika), Marina RONZHINA (203 Česká republika), Tibor STRAČINA (703 Slovensko, domácí), Veronika OLEJNÍČKOVÁ (203 Česká republika, domácí), Jana KOLAROVA (203 Česká republika) a Marie NOVÁKOVÁ (203 Česká republika, garant, domácí).
Vydání Washington, Computing in Cardiology 2016, od s. 409-412, 4 s. 2017.
Nakladatel IEEE Computer Society
Další údaje
Originální jazyk angličtina
Typ výsledku Stať ve sborníku
Obor 30105 Physiology
Stát vydavatele Spojené státy
Utajení není předmětem státního či obchodního tajemství
Forma vydání tištěná verze "print"
Kód RIV RIV/00216224:14110/17:00094617
Organizační jednotka Lékařská fakulta
ISBN 978-1-5090-0896-4
ISSN 2325-8861
UT WoS 000405710400103
Klíčová slova anglicky Response of Ventricular Repolarization Parameters
Štítky EL OK
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Soňa Böhmová, učo 232884. Změněno: 13. 3. 2018 14:00.
Anotace
Heart rate dependency of ventricular repolarization (VR) parameters has been a well known phenomenon for many years. Other contributing factors, such as Mechano-electric Coupling, are still under investigation. In this work, we analyze step response of VR parameters after abrupt change in mechanical end-diastolic load. 10 isolated rabbit hearts were perfused in Working Heart mode. The protocol consisted of abrupt changes in preload level of 3 cm/fcO. Left ventricle electric activity was recorded by seven unipolar leads at sampling frequency 10 kHz. A second-order transfer function model was used to identify basic parameters of Q.TEND and QTPEAK step responses, detected in reconstructed global pseudo-lead. Results show inverse relationship between changes in the preload and the length of QT related intervals. Increase of the preload causes significant (p<0.05) shortening of both intervals within the range of 1.6-26.9 ms. On the contrary, preload decreasing leads to prolongation of repolarization parameters, however, with significantly lower (p<0.05) average magnitude. Dynamic response is highly individual among each heart. Average time needed to reach stable QT in our data is 336.0 seconds, while min. and max. value is 41.4 and 894.0 seconds, respectively.
Návaznosti
GAP102/12/2034, projekt VaVNázev: Analýza vztahu mezi elektrickými ději a průtokem krve u srdečních komor
Investor: Grantová agentura ČR, Analýza vztahu mezi elektrickými ději a průtokem krve u srdečních komor
MUNI/A/1326/2014, interní kód MUNázev: Kardiovaskulární systém od buňky k lůžku pacienta (Akronym: KASBUNPAC)
Investor: Masarykova univerzita, Kardiovaskulární systém od buňky k lůžku pacienta, DO R. 2020_Kategorie A - Specifický výzkum - Studentské výzkumné projekty
VytisknoutZobrazeno: 26. 4. 2024 21:26