BRADA, Michal, David PROCHAZKA, Pavel POŘÍZKA, Jan NOVOTNÝ, Karel NOVOTNÝ a Jozef KAISER. Comparison of approaches for Laser-Induced Breakdown Spectroscopy analyses of liquid suspensions. In 9-th International Conference on Laser-Induced Breakdown Spectroscopy LIBS. 2016.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Comparison of approaches for Laser-Induced Breakdown Spectroscopy analyses of liquid suspensions
Autoři BRADA, Michal (203 Česká republika), David PROCHAZKA (203 Česká republika), Pavel POŘÍZKA (203 Česká republika), Jan NOVOTNÝ (203 Česká republika), Karel NOVOTNÝ (203 Česká republika, garant, domácí) a Jozef KAISER (203 Česká republika).
Vydání 9-th International Conference on Laser-Induced Breakdown Spectroscopy LIBS, 2016.
Další údaje
Originální jazyk angličtina
Typ výsledku Konferenční abstrakt
Obor 10406 Analytical chemistry
Stát vydavatele Francie
Utajení není předmětem státního či obchodního tajemství
Kód RIV RIV/00216224:14310/16:00093832
Organizační jednotka Přírodovědecká fakulta
Klíčová slova anglicky Laser-Induced Breakdown Spectroscopy; analysis of suspensions; liquid jet
Změnil Změnil: doc. Mgr. Karel Novotný, Ph.D., učo 17748. Změněno: 8. 3. 2017 15:48.
Anotace
Here we present complex comparison of several approaches suggested for further in-situ LIBS analysis of liquid suspensions. The in-situ LIBS analysis of suspensions is still a challenging task due to complications related to poor shot-to-shot repeatability when compared to the LIBS analysis of solids. This is attributed mainly to laser-matter coupling and instability of analyzed liquid surface position, and partially to sample inhomogeneity. There are several approaches conventionally used for direct analyses of suspensions such as the analysis of static liquid bulk, liquid jet, droplets, or aerosols. These approaches enable direct analysis applicable to e.g. online monitoring of industrial processes, analysis of contaminated waters etc., but they suffer mainly from high fluctuations in detected signal and moderate limits of detection. Additionally, indirect way of suspensions analysis can be done after drying and/or deposition on a filter. In this study the optimization of most feasible methodological approach was based on following significant parameters: volume of suspension needed for the analysis, limits of detection (in respect to selected toxic and heavy metals), repeatability of shot-to-shot analysis (relative standard deviation), sample preparation time, and total time of analysis.
Návaznosti
LQ1601, projekt VaVNázev: CEITEC 2020 (Akronym: CEITEC2020)
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, CEITEC 2020
VytisknoutZobrazeno: 26. 4. 2024 03:13