Další formáty:
BibTeX
LaTeX
RIS
@article{1384810, author = {Košťál, Michal and Šoltés, Jaroslav and Viererbl, Ladislav and Matěj, Zdeněk and Cvachovec, František and Rypar, Vojtěch and Losa, Evžen}, article_location = {Amsterdam}, article_number = {October 2017}, doi = {http://dx.doi.org/10.1016/j.apradiso.2017.06.026}, keywords = {LVR-15; Neutron spectrometry; Stilbene; Detector calibration; Si neutron filter; Reactor dosimetry}, language = {eng}, issn = {0969-8043}, journal = {Applied Radiation and Isotopes}, title = {Measurement of Neutron Spectra in a Silicon Filtered Neutron Beam Using Stilbene Detectors at the LVR-15 Research Reactor}, url = {http://www.sciencedirect.com/science/article/pii/S0969804317301732}, volume = {128}, year = {2017} }
TY - JOUR ID - 1384810 AU - Košťál, Michal - Šoltés, Jaroslav - Viererbl, Ladislav - Matěj, Zdeněk - Cvachovec, František - Rypar, Vojtěch - Losa, Evžen PY - 2017 TI - Measurement of Neutron Spectra in a Silicon Filtered Neutron Beam Using Stilbene Detectors at the LVR-15 Research Reactor JF - Applied Radiation and Isotopes VL - 128 IS - October 2017 SP - 41-48 EP - 41-48 PB - Elsevier SN - 09698043 KW - LVR-15 KW - Neutron spectrometry KW - Stilbene KW - Detector calibration KW - Si neutron filter KW - Reactor dosimetry UR - http://www.sciencedirect.com/science/article/pii/S0969804317301732 N2 - A well-defined neutron spectrum is an essential tool for calibration and tests of spectrometry and dosimetry detectors, and evaluation methods for spectra processing. Many of the nowadays used neutron standards are based on a fission spectrum which has a smooth character. In recent time, at the LVR-15 research reactor in Rez, an alternative approach was tested for the needs of fast neutron spectrometry detector calibration. This process comprises detector tests in a neutron beam, filtered by one meter of single-crystalline silicon, which contains several significant peaks in the fast neutron energy range. Tests in such a kind of field can possibly reveal specific problems in the deconvolution matrix of the detection system, which may stay hidden in fields with a smooth character and can provide a tool for a proper energy calibration. Test with several stilbene scintillator crystals in two different beam configurations supplemented by Monte-Carlo transport calculation have been carried out. The results have shown a high level of agreement between the experimental data and simulation, proving thus the accuracy of the used deconvolution matrix. The chosen approach can, thus, provide a well-defined neutron reference field with a peak character for further tests of spectra evaluation methods and scintillation detector energy calibration. ER -
KOŠŤÁL, Michal, Jaroslav ŠOLTÉS, Ladislav VIERERBL, Zdeněk MATĚJ, František CVACHOVEC, Vojtěch RYPAR a Evžen LOSA. Measurement of Neutron Spectra in a Silicon Filtered Neutron Beam Using Stilbene Detectors at the LVR-15 Research Reactor. \textit{Applied Radiation and Isotopes}. Amsterdam: Elsevier, 2017, roč.~128, October 2017, s.~41-48. ISSN~0969-8043. Dostupné z: https://dx.doi.org/10.1016/j.apradiso.2017.06.026.
|