2017
Complex interaction of subsequent surface streamers via deposited charge: a high- resolution experimental study
HODER, Tomáš; Petr SYNEK; Dusan CHORVAT; Jozef RÁHEĽ; Ronny BRANDENBURG et al.Základní údaje
Originální název
Complex interaction of subsequent surface streamers via deposited charge: a high- resolution experimental study
Autoři
Vydání
Plasma Physics and Controlled Fusion, Bristol, IOP PUBLISHING LTD, 2017, 0741-3335
Další údaje
Jazyk
angličtina
Typ výsledku
Článek v odborném periodiku
Obor
10305 Fluids and plasma physics
Stát vydavatele
Velká Británie a Severní Irsko
Utajení
není předmětem státního či obchodního tajemství
Odkazy
Impakt faktor
Impact factor: 3.032
Označené pro přenos do RIV
Ano
Kód RIV
RIV/00216224:14310/17:00094832
Organizační jednotka
Přírodovědecká fakulta
UT WoS
EID Scopus
Klíčová slova anglicky
barrier discharge; streamer; surface charge; electric field; air; surface interaction
Změněno: 22. 3. 2021 19:04, doc. RNDr. Jozef Ráheľ, PhD.
Anotace
V originále
The coplanar barrier discharge in synthetic air at 30 kPa pressure was studied by time-correlated single photon counting enhanced optical emission spectroscopy, far-field microscopy enhanced intensified CCD camera and sensitive current measurements. The discharge operated in a regime where two subsequent microdischarges appeared within the same voltage half-period. The electrical analysis of the barrier discharge setup enabled us to quantify charge transfer and the effective electric field development. During the second microdischarge the positive surface streamers follow the interface (triple-line) between the area of deposited charge from the previous one and the area of uncharged dielectric surface. It is shown that additional branching and flashes of surface streamers are responsible for the increased spatial complexity of the deposited surface charges at high overvoltage. A suppressed streamer propagating over the area of deposited surface charge was tracked and the evidence of surface streamer reconnection is presented. A spatiotemporal distribution (resolution of 120 ps and 100 um) of the reduced electric field strength was obtained for both microdischarges from the recorded luminosities of the molecular nitrogen. The reduced electric field of positive streamers in the first microdischarge reached 1200 Td. For the second one, the electric field values for the streamer at the triple-line are slightly lower than that, while for the suppressed streamers are even higher.
Návaznosti
| CZ.1.05/2.1.00/03.0086, interní kód MU |
| ||
| GJ16-09721Y, projekt VaV |
| ||