HODER, Tomáš, Petr SYNEK, Dusan CHORVAT, Jozef RÁHEĽ, Ronny BRANDENBURG a Mirko ČERNÁK. Complex interaction of subsequent surface streamers via deposited charge: a high- resolution experimental study. Plasma Physics and Controlled Fusion. Bristol: IOP PUBLISHING LTD, 2017, roč. 59, č. 7, s. "07400101"-"07400111", 11 s. ISSN 0741-3335. Dostupné z: https://dx.doi.org/10.1088/1361-6587/aa6ea2.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Complex interaction of subsequent surface streamers via deposited charge: a high- resolution experimental study
Autoři HODER, Tomáš (203 Česká republika, garant, domácí), Petr SYNEK (203 Česká republika, domácí), Dusan CHORVAT (703 Slovensko), Jozef RÁHEĽ (703 Slovensko, domácí), Ronny BRANDENBURG (276 Německo) a Mirko ČERNÁK (703 Slovensko, domácí).
Vydání Plasma Physics and Controlled Fusion, Bristol, IOP PUBLISHING LTD, 2017, 0741-3335.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 10305 Fluids and plasma physics
Stát vydavatele Velká Británie a Severní Irsko
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 3.032
Kód RIV RIV/00216224:14310/17:00094832
Organizační jednotka Přírodovědecká fakulta
Doi http://dx.doi.org/10.1088/1361-6587/aa6ea2
UT WoS 000402411800001
Klíčová slova anglicky barrier discharge; streamer; surface charge; electric field; air; surface interaction
Štítky NZ, rivok
Změnil Změnil: doc. RNDr. Jozef Ráheľ, PhD., učo 169224. Změněno: 22. 3. 2021 19:04.
Anotace
The coplanar barrier discharge in synthetic air at 30 kPa pressure was studied by time-correlated single photon counting enhanced optical emission spectroscopy, far-field microscopy enhanced intensified CCD camera and sensitive current measurements. The discharge operated in a regime where two subsequent microdischarges appeared within the same voltage half-period. The electrical analysis of the barrier discharge setup enabled us to quantify charge transfer and the effective electric field development. During the second microdischarge the positive surface streamers follow the interface (triple-line) between the area of deposited charge from the previous one and the area of uncharged dielectric surface. It is shown that additional branching and flashes of surface streamers are responsible for the increased spatial complexity of the deposited surface charges at high overvoltage. A suppressed streamer propagating over the area of deposited surface charge was tracked and the evidence of surface streamer reconnection is presented. A spatiotemporal distribution (resolution of 120 ps and 100 um) of the reduced electric field strength was obtained for both microdischarges from the recorded luminosities of the molecular nitrogen. The reduced electric field of positive streamers in the first microdischarge reached 1200 Td. For the second one, the electric field values for the streamer at the triple-line are slightly lower than that, while for the suppressed streamers are even higher.
Návaznosti
CZ.1.05/2.1.00/03.0086, interní kód MUNázev: CEPLANT - Regionální VaV centrum pro nízkonákladové plazmové a nanotechnologické povrchové úpravy
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, CEPLANT - Regionální VaV centrum pro nízkonákladové plazmové a nanotechnologické povrchové úpravy, 2.1 Regionální VaV centra
GJ16-09721Y, projekt VaVNázev: Pokročilé experimentální studium přechodných povrchových výbojů
Investor: Grantová agentura ČR, Pokročilé experimentální studium přechodných povrchových výbojů
LO1411, projekt VaVNázev: Rozvoj centra pro nízkonákladové plazmové a nanotechnologické povrchové úpravy (Akronym: CEPLANT plus)
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, Rozvoj centra pro nízkonákladové plazmové a nanotechnologické povrchové úpravy
VytisknoutZobrazeno: 25. 4. 2024 18:28