NEDOMA, Jan, Marcel FAJKUS, Stanislav KEPAK, Jakub CUBIK, Radana KAHANKOVA, Petr JANKŮ, Vladimír VASINEK, Homer NAZERAN a Radek MARTINEK. NONINVASIVE FETAL HEART RATE MONITORING: VALIDATION OF PHONOCARDIOGRAPHY-BASED FIBER-OPTIC SENSING AND ADAPTIVE FILTERING USING THE NLMS ALGORITHM. Advances in Electrical and Electronic Engineering. Ostrava: Vysoká škola báňská - Technická univerzita, roč. 15, č. 3, s. 544-552. ISSN 1336-1376. doi:10.15598/aeee.v15i3.2195. 2017.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název NONINVASIVE FETAL HEART RATE MONITORING: VALIDATION OF PHONOCARDIOGRAPHY-BASED FIBER-OPTIC SENSING AND ADAPTIVE FILTERING USING THE NLMS ALGORITHM
Autoři NEDOMA, Jan (203 Česká republika), Marcel FAJKUS (203 Česká republika), Stanislav KEPAK (203 Česká republika), Jakub CUBIK (203 Česká republika), Radana KAHANKOVA (203 Česká republika), Petr JANKŮ (203 Česká republika, garant, domácí), Vladimír VASINEK (203 Česká republika), Homer NAZERAN (203 Česká republika) a Radek MARTINEK (203 Česká republika).
Vydání Advances in Electrical and Electronic Engineering, Ostrava, Vysoká škola báňská - Technická univerzita, 2017, 1336-1376.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 20200 2.2 Electrical engineering, Electronic engineering, Information engineering
Stát vydavatele Česká republika
Utajení není předmětem státního či obchodního tajemství
Kód RIV RIV/00216224:14110/17:00100124
Organizační jednotka Lékařská fakulta
Doi http://dx.doi.org/10.15598/aeee.v15i3.2195
UT WoS 000424330700019
Klíčová slova anglicky ElectroMagnetic Interference (EMI); fetal Heart Rate (fHR); fetal PhonoCardioGraphy (fPCG); Fiber-optic sensor; maternal PhonoCardioGraphy (mPCG); Normalized Least Mean Square (NLMS) algorithm; PolyDiMethylSiloxane (PDMS)
Štítky EL OK
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Soňa Böhmová, učo 232884. Změněno: 17. 5. 2018 13:00.
Anotace
Here we present the evaluation results of our novel noninvasive phonocardiographic-based fiberoptic sensor for fetal Heart Rate (fHR) detection using adaptive filtering and the NLMS Algorithm. The sensor uses two interferometric probes encapsulated inside a PolyDiMethylSiloxane (PDMS) polymer. Based on real data acquired from pregnant women in a suitable research laboratory environment, once they had given their written informed consents, we created a simplified dynamic signal model of the distribution of maternal and fetal heart sounds inside the maternal body. Building upon this signal model, we verified the functionality of our novel fiber-optic sensor and its associated adaptive filtering system using the NLMS Algorithm. The main reason why we chose this technology to develop our system was that it allows monitoring the fHR without exposing the fetus to any external energies or radiation (in contrast to the ultrasound-based Cardiotocography Method). We used objective criteria such as: Signal to Noise Ratios: SNRin, SNR o u t and Percentage Root-mean-square Difference (PRD) for our evaluations.
VytisknoutZobrazeno: 29. 3. 2024 09:38