SALYK, Ota, Jan VÍTEČEK, Lukáš OMASTA, Eva ŠAFAŘÍKOVÁ, Stanislav STŘÍTESKÝ, Martin VALA a Martin WEITER. Organic Electrochemical Transistor Microplate for Real-Time Cell Culture Monitoring. Applied Sciences-Basel. BASEL, SWITZERLAND: MDPI AG, 2017, roč. 7, č. 10, s. nestránkováno, 10 s. ISSN 2076-3417. Dostupné z: https://dx.doi.org/10.3390/app7100998.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Organic Electrochemical Transistor Microplate for Real-Time Cell Culture Monitoring
Autoři SALYK, Ota (203 Česká republika, garant), Jan VÍTEČEK (203 Česká republika, domácí), Lukáš OMASTA (203 Česká republika), Eva ŠAFAŘÍKOVÁ (203 Česká republika, domácí), Stanislav STŘÍTESKÝ (203 Česká republika), Martin VALA (203 Česká republika) a Martin WEITER (203 Česká republika).
Vydání Applied Sciences-Basel, BASEL, SWITZERLAND, MDPI AG, 2017, 2076-3417.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 10400 1.4 Chemical sciences
Stát vydavatele Švýcarsko
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 1.689
Kód RIV RIV/00216224:14310/17:00100375
Organizační jednotka Přírodovědecká fakulta
Doi http://dx.doi.org/10.3390/app7100998
UT WoS 000414457800036
Klíčová slova anglicky OECT; screen printing; organic electrochemical transistor; PEDOT:PSS; microplate; multi-electrode array; cell culture
Štítky NZ, rivok
Příznaky Recenzováno
Změnil Změnila: Ing. Nicole Zrilić, učo 240776. Změněno: 10. 4. 2018 11:52.
Anotace
Human cell cultures provide a potentially powerful means for pharmacological and toxicological research. A microplate with a multielectrode array of 96 organic electrochemical transistors (OECTs) based on the semiconductive polymer poly(3,4-ethylenedioxythio-phene):poly(styrene sulfonic acid) PEDOT:PSS was developed and fabricated by the screen printing method. It consists of a microplate of a 12 × 8 chimney-well array with transistors on the bottom. The OECT is circular with a channel of 1.5 mm2 in the centre surrounded by the circular gate electrode. The device is designed for electrogenic cell monitoring. Simulations with the electrolyte revealed good electrical characteristics and indicated the setup information of the experimental conditions. A transconductance of g = 1.4 mS was achieved in the wide range of gate voltages Vgs = ±0.4 V when the drain potential Vds = -0.735 V was set and the long term relaxation was compensated for. The time constant 0.15 s limited by the channel-electrolyte charge electrical double layer (EDL) capacitance was measured. The device was tested on a 3T3 fibroblast cell culture and the sudden environmental changes were recorded. The living cells can be observed on the channel of the OECT and during electrical stimulation by gate voltage, as well as during the source current response.
VytisknoutZobrazeno: 26. 4. 2024 22:03