2018
The effect of local power increase on neutron flux in internal parts of the VVER-1000 Mock-Up in LR-0 reactor
KOŠŤÁL, M., E. LOSA, M. SCHULC, J. ŠIMON, D. HARUT et. al.Základní údaje
Originální název
The effect of local power increase on neutron flux in internal parts of the VVER-1000 Mock-Up in LR-0 reactor
Autoři
KOŠŤÁL, M. (203 Česká republika), E. LOSA (203 Česká republika), M. SCHULC (203 Česká republika), J. ŠIMON (203 Česká republika), D. HARUT (203 Česká republika), V. KLUPÁK (203 Česká republika), T. CZAKOJ (203 Česká republika), V. JUŘÍČEK (203 Česká republika), Zdeněk MATĚJ (203 Česká republika, garant, domácí), František CVACHOVEC (203 Česká republika) a V. RYPAR (203 Česká republika)
Vydání
Annals of Nuclear Energy, 2018, 0306-4549
Další údaje
Jazyk
angličtina
Typ výsledku
Článek v odborném periodiku
Obor
10304 Nuclear physics
Stát vydavatele
Nizozemské království
Utajení
není předmětem státního či obchodního tajemství
Impakt faktor
Impact factor: 1.380
Kód RIV
RIV/00216224:14330/18:00103750
Organizační jednotka
Fakulta informatiky
UT WoS
000444668200054
Klíčová slova anglicky
LR-0; Neutron spectrometry; Reactor dosimetry; VVER-1000; Mock-Up
Změněno: 29. 4. 2019 15:37, RNDr. Pavel Šmerk, Ph.D.
Anotace
V originále
The neutron flux distribution in the internal parts of a reactor is an important parameter which affects the absorbed dose, temperature, and gas production in the materials. Therefore, the knowledge of neutron flux distribution, for example in the baffle, is important for estimation of the radiation-induced swelling and activation of this internal component. The power distribution in the periphery fuel assemblies, mostly the lateral 2–3 pin rows, has considerable influence on neutron and gamma flux in the internal reactor elements. The power distribution in the core is mostly calculated by the reactor operator using diffusion codes. These data are used as an input for transport calculations, e.g., with Monte Carlo for the fluences, displacements per atoms, gamma heating and other important values for radiation damage estimation. This paper aims to compare the experimental and calculated reaction rate distribution in a mock-up of VVER-1000 (VVER-1000 Mock-Up) internals placed in the LR- 0 reactor and compares these quantities in case of a partial change of enrichment in one fuel assembly adjacent to the baffle simulator.