KOUDELKOVA, Zuzana, Tomáš SYROVY, Pavlína AMBROZOVA, Zdeněk MORAVEC, Lubomír KUBAC, David HYNEK, Lukáš RICHTERA a Vojtěch ADAM. Determination of Zinc, Cadmium, Lead, Copper and Silver Using a Carbon Paste Electrode and a Screen Printed Electrode Modified with Chromium(III) Oxide. Online. Sensors. Basel: MDPI AG, 2017, roč. 17, č. 8, s. 1832-1845. ISSN 1424-8220. Dostupné z: https://dx.doi.org/10.3390/s17081832. [citováno 2024-04-24]
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Determination of Zinc, Cadmium, Lead, Copper and Silver Using a Carbon Paste Electrode and a Screen Printed Electrode Modified with Chromium(III) Oxide
Autoři KOUDELKOVA, Zuzana (203 Česká republika), Tomáš SYROVY (203 Česká republika), Pavlína AMBROZOVA (203 Česká republika), Zdeněk MORAVEC (203 Česká republika, domácí), Lubomír KUBAC (203 Česká republika), David HYNEK (203 Česká republika), Lukáš RICHTERA (203 Česká republika, garant) a Vojtěch ADAM (203 Česká republika)
Vydání Sensors, Basel, MDPI AG, 2017, 1424-8220.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 10406 Analytical chemistry
Stát vydavatele Švýcarsko
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 2.475
Kód RIV RIV/00216224:14310/17:00120390
Organizační jednotka Přírodovědecká fakulta
Doi http://dx.doi.org/10.3390/s17081832
UT WoS 000408576900135
Klíčová slova anglicky carbon paste; chromium; electrochemistry; heavy metals; screen-printed electrode; silver
Štítky rivok
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Mgr. Marie Šípková, DiS., učo 437722. Změněno: 9. 11. 2021 16:52.
Anotace
In this study, the preparation and electrochemical application of a chromium(III) oxide modified carbon paste electrode (Cr-CPE) and a screen printed electrode (SPE), made from the same material and optimized for the simple, cheap and sensitive simultaneous determination of zinc, cadmium, lead, copper and the detection of silver ions, is described. The limits of detection and quantification were 25 and 80 mu g center dot L-1 for Zn(II), 3 and 10 mu g center dot L-1 for Cd(II), 3 and 10 mu g center dot L-1 for Pb(II), 3 and 10 mu g center dot L-1 for Cu(II), and 3 and 10 mu g center dot L-1 for Ag(I), respectively. Furthermore, this promising modification was transferred to the screen-printed electrode. The limits of detection for the simultaneous determination of zinc, cadmium, copper and lead on the screen printed electrodes were found to be 350 mu g center dot L-1 for Zn(II), 25 mu g center dot L-1 for Cd(II), 3 mu g center dot L-1 for Pb(II) and 3 mu g center dot L-1 for Cu(II). Practical usability for the simultaneous detection of these heavy metal ions by the Cr-CPE was also demonstrated in the analyses of wastewaters.
VytisknoutZobrazeno: 24. 4. 2024 02:52