VANGENECHTEN, I., K. MAYGER, Petr SMEJKAL, Ondřej ZAPLETAL, J.J. MICHIELS, G.W. MOORE a A. GADISSEUR. A comparative analysis of different automated von Willebrand factor glycoprotein Ib-binding activity assays in well typed von Willebrand disease patients. Journal of Thrombosis and Haemostasis. HOBOKEN: WILEY, 2018, roč. 16, č. 7, s. 1268-1277. ISSN 1538-7933. Dostupné z: https://dx.doi.org/10.1111/jth.14145.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název A comparative analysis of different automated von Willebrand factor glycoprotein Ib-binding activity assays in well typed von Willebrand disease patients
Autoři VANGENECHTEN, I. (56 Belgie, garant), K. MAYGER (826 Velká Británie a Severní Irsko), Petr SMEJKAL (203 Česká republika, domácí), Ondřej ZAPLETAL (203 Česká republika), J.J. MICHIELS (56 Belgie), G.W. MOORE (826 Velká Británie a Severní Irsko) a A. GADISSEUR (56 Belgie).
Vydání Journal of Thrombosis and Haemostasis, HOBOKEN, WILEY, 2018, 1538-7933.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 30205 Hematology
Stát vydavatele Spojené státy
Utajení není předmětem státního či obchodního tajemství
Impakt faktor Impact factor: 4.662
Kód RIV RIV/00216224:14110/18:00104167
Organizační jednotka Lékařská fakulta
Doi http://dx.doi.org/10.1111/jth.14145
UT WoS 000437289500005
Klíčová slova anglicky classification; ristocetin cofactor; subtypes; Von Willebrand disease; von Willebrand factor
Štítky 14110616, rivok
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Soňa Böhmová, učo 232884. Změněno: 2. 5. 2019 14:17.
Anotace
Background: von Willebrand disease (VWD) is an inherited bleeding disorder caused by quantitative (type 1 and 3) or qualitative (type 2) von Willebrand factor (VWF) defect. VWD diagnosis and classification require numerous laboratory tests. VWF: glycoprotein Ib (GPIb)-binding activity assays are used to distinguish type 1 from type 2 VWD. Objectives: Three different automated VWF:GPIb-binding activity assays were compared. Patients and methods: BC-VWF:RCo (Siemens Healthcare Diagnostics), HemosIL((R)) VWF:RCo (Instrumentation Laboratory) and INNOVANCE((R)) VWF:Ac (Siemens Healthcare Diagnostics) were performed in a well typed VWD cohort (n = 142). Results: Based on the three most used VWD parameters (FVIII:C, VWF:Ag and VWF:GPIb-binding activity) and using a cut-off of <0.70 for type 2 VWD revealed sensitivity and specificity of, respectively, 92% and 72.4% for VWF:RCo/VWF:Ag, 84% and 89.7% for VWF:GPIbR/VWF:Ag, and 92% and 85.1% for VWF:GPIbM/VWF:Ag, whereas a lowered cut-off of < 0.60 resulted in reduced sensitivity with increased specificity for all assays. Conclusion: VWD classification based on FVIII:C, VWF:Ag and VWF:GPIb-binding activity revealed an overall problem with normal VWF:GPIb-binding activity/VWF:Ag within type 2, especially type 2A/IIE. Although all assays were practically identical, BC-VWF:RCo had higher %CV compared with both new assays but comparable lower limit of quantification (LLOQ) similar to 4 IU dL(-1). No clear improved distinction between type 1 and 2 VWD with new assays was seen. BC-VWF:RCo and HemosIL((R)) are ristocetin dependent, whereas INNOVANCE((R)) does not rely upon ristocetin and is not influenced by VWF polymorphisms increasing VWF:GPIb-binding activity levels. INNOVANCE((R)) seems to be the best choice as a first-line VWF:GPIb-binding activity assay, providing the best balance between sensitivity and specificity for type 2 VWD.
VytisknoutZobrazeno: 25. 5. 2024 02:54