J 2018

Time-Efficient Perfusion Imaging Using DCE- and DSC-MRI

MACÍČEK, Ondřej, Radovan JIŘÍK, Jan MIKULKA, Michal BARTOŠ, Andrea ŠPRLÁKOVÁ-PUKOVÁ et. al.

Základní údaje

Originální název

Time-Efficient Perfusion Imaging Using DCE- and DSC-MRI

Autoři

MACÍČEK, Ondřej (203 Česká republika, garant), Radovan JIŘÍK (203 Česká republika), Jan MIKULKA (203 Česká republika), Michal BARTOŠ (203 Česká republika), Andrea ŠPRLÁKOVÁ-PUKOVÁ (203 Česká republika, domácí), Miloš KEŘKOVSKÝ (203 Česká republika, domácí), Zenon STARČUK (203 Česká republika), Karel BARTUŠEK (203 Česká republika) a Torfinn TAXT (578 Norsko)

Vydání

Measurement Science Review, WARSAW, UM SAV, 2018, 1335-8871

Další údaje

Jazyk

angličtina

Typ výsledku

Článek v odborném periodiku

Obor

30224 Radiology, nuclear medicine and medical imaging

Stát vydavatele

Polsko

Utajení

není předmětem státního či obchodního tajemství

Impakt faktor

Impact factor: 1.122

Kód RIV

RIV/00216224:14110/18:00105311

Organizační jednotka

Lékařská fakulta

UT WoS

000452196100006

Klíčová slova anglicky

Perfusion imaging; contrast agents; brain tumors; DCE-MRI; DSC-MRI

Štítky

Příznaky

Mezinárodní význam, Recenzováno
Změněno: 11. 2. 2019 14:27, Soňa Böhmová

Anotace

V originále

Dynamic contrast enhanced MRI (DCE-MRI) and dynamic susceptibility contrast MRI (DSC-MRI) are perfusion imaging techniques used mainly for clinical and preclinical measurement of vessel permeability and capillary blood flow, respectively. It is advantageous to apply both methods to exploit their complementary information about the perfusion status of the tissue. We propose a novel acquisition method that combines advantages of the current simultaneous and sequential acquisition. The proposed method consists of a DCE-MRI acquisition interrupted by DSC-MRI acquisition. A new method for processing of the DCE-MRI data is proposed which takes the interleaved acquisition into account. Analysis of both the DCE- and DSC-MRI data is reformulated so that they are approximated by the same pharmacokinetic model (constrained distributed capillary adiabatic tissue homogeneity model). This provides a straightforward evaluation of the methodology as some of the estimated DCE- and DSC-MRI perfusion parameters should be identical. Evaluation on synthetic data showed an acceptable precision and no apparent bias introduced by the interleaved character of the DCE-MRI acquisition. Intravascular perfusion parameters obtained from clinical glioma data showed a fairly high correlation of blood flow estimates from DCE- and DSC-MRI, however, an unknown scaling factor was still present mainly because of the tissue-specific r(2)* relaxivity. The results show validity of the proposed acquisition method. They also indicate that simultaneous processing of both DCE- and DSC-MRI data with joint estimation of some perfusion parameters (included in both DCE- and DSC-MRI) might be possible to increase the reliability of the DCE- and DSC-MRI methods alone.

Návaznosti

CZ.02.1.01/0.0/0.0/16_013/0001775, interní kód MU
(Kód CEP: EF16_013/0001775)
Název: Modernizace a podpora výzkumných aktivit národní infrastruktury pro biologické a medicínské zobrazování Czech-BioImaging
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, Modernizace a podpora výzkumných aktivit národní infrastruktury pro biologické a medicínské zobrazování Czech-BioImaging, PO 1 Posilování kapacit pro kvalitní výzkum
LM2015062, projekt VaV
Název: Národní infrastruktura pro biologické a medicínské zobrazování
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, National research infrastructure for biological and medical imaging