HRDLIČKA, Aleš, Jitka HEGROVÁ, Karel NOVOTNÝ, Viktor KANICKÝ, David PROCHAZKA, Jan NOVOTNÝ, Pavlína MODLITBOVÁ, Lucia SLÁDKOVÁ, Pavel POŘÍZKA a Jozef KAISER. Sulfur determination in concrete samples using laser-induced breakdown spectroscopy and limestone standards. Spectrochimica Acta, Part B: Atomic Spectroscopy. Oxford: Elsevier, 2018, roč. 142, April 2018, s. 8-13. ISSN 0584-8547. Dostupné z: https://dx.doi.org/10.1016/j.sab.2018.01.015.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Sulfur determination in concrete samples using laser-induced breakdown spectroscopy and limestone standards
Autoři HRDLIČKA, Aleš (203 Česká republika, garant, domácí), Jitka HEGROVÁ (203 Česká republika), Karel NOVOTNÝ (203 Česká republika, domácí), Viktor KANICKÝ (203 Česká republika, domácí), David PROCHAZKA (203 Česká republika), Jan NOVOTNÝ (203 Česká republika), Pavlína MODLITBOVÁ (203 Česká republika), Lucia SLÁDKOVÁ (703 Slovensko), Pavel POŘÍZKA (203 Česká republika) a Jozef KAISER (203 Česká republika).
Vydání Spectrochimica Acta, Part B: Atomic Spectroscopy, Oxford, Elsevier, 2018, 0584-8547.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 10406 Analytical chemistry
Stát vydavatele Velká Británie a Severní Irsko
Utajení není předmětem státního či obchodního tajemství
WWW odkaz na článek
Impakt faktor Impact factor: 3.101
Kód RIV RIV/00216224:14310/18:00106041
Organizační jednotka Přírodovědecká fakulta
Doi http://dx.doi.org/10.1016/j.sab.2018.01.015
UT WoS 000430033200002
Klíčová slova anglicky Sulfur; Concrete; Limestone; Standard; Laser; Induced; Breakdown; Spectroscopy; Inductively coupled; Plasma; Mass spectrometry; Triple; Quadrupole
Štítky rivok
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnil: Mgr. Michal Petr, učo 65024. Změněno: 23. 4. 2024 14:13.
Anotace
A LIBS equipment operating at 532 nm was optimized and used for sulfur determination in concrete samples. The influence of He atmosphere in a gas-tight chamber (1000-200 mbar) on S I 921.29 nm line sensitivity, signal-to-background and signal-to-noise ratio was studied at gate delays 100-2000 ns. Wide range of gate delays from 500 to about 1000 ns and pressures from several hundreds of mbar to the atmospheric pressure can be used for the desired detection of sulfur. The LIBS quantification was done using a simple calibration method. A synthetic limestone enriched by defined amounts of sodium sulfate was newly employed for direct quantification of S in concrete. This powder material was pressed into pellets and ablated with the LIBS system. The average content of sulfur as SO3 in the samples was 0.41-0.70 wt% by LIBS and 0.43-0.61 wt% by a reference standard procedure employing gravimetry and Inductively Coupled Plasma Triple Quad Mass Spectrometry (ICP-QQQMS). The uncertainty of the yielded LIBS results covers also the dispersion of the points in the calibration line and ranges from 16 to 28% at the probability level of 95%. The uncertainty of the ICP-QQQMS results was almost 10%. No correction on different signal response on the limestone and on the concrete was necessary. (C) 2018 Elsevier B.V. All rights reserved.
Návaznosti
LQ1601, projekt VaVNázev: CEITEC 2020 (Akronym: CEITEC2020)
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, CEITEC 2020
VytisknoutZobrazeno: 23. 5. 2024 08:28