ANDRAŠINA, Tomáš, Tomáš GROLICH, Michal CRHA, Ladislav STEHLIK, Tomáš ROHAN, Červinka DALIBOR, Veronika NOVOTNÁ, Vladan BERNARD, Iva SVOBODOVÁ a Vlastimil VÁLEK. The Methodology for Endoluminal Irreversible Electroporation in Porcine Models. Acta Veterinaria Brno. Brno: Veterinární a farmaceutická univerzita Brno, 2019, roč. 88, č. 2, s. 201-211. ISSN 0001-7213. Dostupné z: https://dx.doi.org/10.2754/avb201988020201.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název The Methodology for Endoluminal Irreversible Electroporation in Porcine Models
Autoři ANDRAŠINA, Tomáš (703 Slovensko, garant, domácí), Tomáš GROLICH (203 Česká republika, domácí), Michal CRHA (203 Česká republika), Ladislav STEHLIK (203 Česká republika), Tomáš ROHAN (203 Česká republika, domácí), Červinka DALIBOR (203 Česká republika), Veronika NOVOTNÁ (203 Česká republika), Vladan BERNARD (203 Česká republika, domácí), Iva SVOBODOVÁ (203 Česká republika, domácí) a Vlastimil VÁLEK (203 Česká republika, domácí).
Vydání Acta Veterinaria Brno, Brno, Veterinární a farmaceutická univerzita Brno, 2019, 0001-7213.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 30224 Radiology, nuclear medicine and medical imaging
Stát vydavatele Česká republika
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 0.566
Kód RIV RIV/00216224:14110/19:00108487
Organizační jednotka Lékařská fakulta
Doi http://dx.doi.org/10.2754/avb201988020201
UT WoS 000509755300008
Klíčová slova anglicky biliary ablation; magnetic resonance imaging; intraductal ablation; experimental study
Štítky 14110112, 14110216, 14110223, 14110511, rivok
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Mgr. Tereza Miškechová, učo 341652. Změněno: 11. 5. 2020 13:01.
Anotace
The aim of work was to describe methodology of surgical technique for endoluminal irreversible electroporation in the biliary tract performed within the perihilar region in porcine models. Endoluminal irreversible electroporation of the common bile duct was performed on 8 porcine models using an endoluminal device inserted during laparotomy. The endoluminal device consisted of 3 electrodes 1 cm in length, attached at 120 degrees around the balloon catheter. The procedure was conducted with following parameters: number of pulses 90, voltage of 1500 V between each couple of electrodes. Cross sectional imaging and histopathological assessment were employed for evaluations of ablation zone. Models were sacrificed in 24 hours and 96 hours after ablation. The treatment was successful in all porcine models. All animals survived the defined study period. Peri-ablation oedema within the hepatoduodenal ligament and adjacent liver tissue could be measured on post-procedural MRI or CT. Perforation in site of ablation developed in one model. Histopathological examination showed heavy regressive changes of ablated tissue. The elastic membranes of adjacent portal vein were preserved in all models. This novel endoluminal modality used within the perihilar region on porcine models is a feasible and well predictable procedure according to our experience. Further studies should explore the optimal protocol of catheter-based ablation to limit complications.
Návaznosti
NV15-32484A, projekt VaVNázev: Využití nových biotechnologií v prevenci a léčbě stenóz žlučových cest
ROZV/24/LF/2018, interní kód MUNázev: LF - Příspěvek na IP 2108
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, LF - Příspěvek na IP 2108, Interní rozvojové projekty
VytisknoutZobrazeno: 19. 7. 2024 23:44