MODLITBOVÁ, Pavlína, Zdeněk FARKA, Matěj PASTUCHA, Pavel POŘÍZKA, Karel NOVOTNÝ, Petr SKLÁDAL a Jozef KAISER. Laser-induced breakdown spectroscopy as a novel readout method for nanoparticle-based immunoassays. Microchimica Acta. Vienna: Springer, 2019, roč. 186, č. 9, s. 1-10. ISSN 0026-3672. Dostupné z: https://dx.doi.org/10.1007/s00604-019-3742-9.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Laser-induced breakdown spectroscopy as a novel readout method for nanoparticle-based immunoassays
Autoři MODLITBOVÁ, Pavlína (203 Česká republika), Zdeněk FARKA (203 Česká republika, domácí), Matěj PASTUCHA (203 Česká republika, domácí), Pavel POŘÍZKA (203 Česká republika), Karel NOVOTNÝ (203 Česká republika, domácí), Petr SKLÁDAL (203 Česká republika, domácí) a Jozef KAISER (203 Česká republika, garant).
Vydání Microchimica Acta, Vienna, Springer, 2019, 0026-3672.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 10406 Analytical chemistry
Stát vydavatele Rakousko
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 6.232
Kód RIV RIV/00216224:14740/19:00110447
Organizační jednotka Středoevropský technologický institut
Doi http://dx.doi.org/10.1007/s00604-019-3742-9
UT WoS 000481742100001
Klíčová slova anglicky Collinear plasma collection; Gold nanoparticles; Laser ablation; Microtiter plate; Sandwich immunoassay; Silver nanoparticles; Streptavidin; Tag-LIBS
Štítky CF NANO, rivok
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Mgr. Pavla Foltynová, Ph.D., učo 106624. Změněno: 31. 3. 2020 21:41.
Anotace
Laser-induced breakdown spectroscopy (LIBS) was examined as a novel method for readout of microtiter plate immunoassays involving nanoparticles (NP). The so-called Tag-LIBS technique is a sensitive method for the detection of specific biomarkers. It was applied to the determination of NP labels using nanosecond ablation sampling. The NP labels were examined from the bottom of a standard 96-well microtiter plate. Thanks to the flexibility of LIBS instrumentation, both the plasma emission collection and the focusing optics arrangements can be collinearly arranged. The experiments showed that silver NPs and gold NPs can be readily quantified on the bottom of the microtiter plate. Utilizing this technique, a sandwich immunoassay for human serum albumin using streptavidin-coated AgNP labels was developed. The assay has a 10 ng·mL-1 detection limit which is comparable to the sensitivity of fluorometric readout. The main advantage of this LIBS technique is its wide scope in which it enables a detection of almost any type of NP labels, irrespective to any fluorescence or catalytic properties. Owing to the immediate signal response, the relatively simple instrumentation also enables assay automation. The LIBS capability of multi-elemental analyses makes it a promising and fast alternative to other readout techniques, in particular with respect to multiplexed detection of biomarkers.
Návaznosti
CZ.02.1.01/0.0/0.0/16_013/0001728, interní kód MUNázev: CEITEC Nano+ (Akronym: CEITEC Nano)
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, CEITEC Nano+, PO 1 Posilování kapacit pro kvalitní výzkum
LM2015043, projekt VaVNázev: Česká infrastruktura pro integrativní strukturní biologii (Akronym: CIISB)
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, Czech Infrastructure for Integrative Structural Biology
LQ1601, projekt VaVNázev: CEITEC 2020 (Akronym: CEITEC2020)
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, CEITEC 2020
VytisknoutZobrazeno: 8. 5. 2024 01:39