2019
Laser-induced breakdown spectroscopy as a novel readout method for nanoparticle-based immunoassays
MODLITBOVÁ, Pavlína; Zdeněk FARKA; Matěj PASTUCHA; Pavel POŘÍZKA; Karel NOVOTNÝ et al.Základní údaje
Originální název
Laser-induced breakdown spectroscopy as a novel readout method for nanoparticle-based immunoassays
Autoři
MODLITBOVÁ, Pavlína; Zdeněk FARKA; Matěj PASTUCHA; Pavel POŘÍZKA; Karel NOVOTNÝ; Petr SKLÁDAL a Jozef KAISER
Vydání
Microchimica Acta, Vienna, Springer, 2019, 0026-3672
Další údaje
Jazyk
angličtina
Typ výsledku
Článek v odborném periodiku
Obor
10406 Analytical chemistry
Stát vydavatele
Rakousko
Utajení
není předmětem státního či obchodního tajemství
Odkazy
Impakt faktor
Impact factor: 6.232
Označené pro přenos do RIV
Ano
Kód RIV
RIV/00216224:14740/19:00110447
Organizační jednotka
Středoevropský technologický institut
UT WoS
EID Scopus
Klíčová slova anglicky
Collinear plasma collection; Gold nanoparticles; Laser ablation; Microtiter plate; Sandwich immunoassay; Silver nanoparticles; Streptavidin; Tag-LIBS
Příznaky
Mezinárodní význam, Recenzováno
Změněno: 2. 11. 2024 19:24, Mgr. Adéla Pešková
Anotace
V originále
Laser-induced breakdown spectroscopy (LIBS) was examined as a novel method for readout of microtiter plate immunoassays involving nanoparticles (NP). The so-called Tag-LIBS technique is a sensitive method for the detection of specific biomarkers. It was applied to the determination of NP labels using nanosecond ablation sampling. The NP labels were examined from the bottom of a standard 96-well microtiter plate. Thanks to the flexibility of LIBS instrumentation, both the plasma emission collection and the focusing optics arrangements can be collinearly arranged. The experiments showed that silver NPs and gold NPs can be readily quantified on the bottom of the microtiter plate. Utilizing this technique, a sandwich immunoassay for human serum albumin using streptavidin-coated AgNP labels was developed. The assay has a 10 ng·mL-1 detection limit which is comparable to the sensitivity of fluorometric readout. The main advantage of this LIBS technique is its wide scope in which it enables a detection of almost any type of NP labels, irrespective to any fluorescence or catalytic properties. Owing to the immediate signal response, the relatively simple instrumentation also enables assay automation. The LIBS capability of multi-elemental analyses makes it a promising and fast alternative to other readout techniques, in particular with respect to multiplexed detection of biomarkers.
Návaznosti
| CZ.02.1.01/0.0/0.0/16_013/0001728, interní kód MU |
| ||
| LM2015043, projekt VaV |
| ||