J 2019

The Influence of False Cardiac Feedback on Autonomic Markers of Arousal

KUŘÁTKOVÁ, Marie, Eva KOZÁKOVÁ, Radek MAREČEK, Robert ROMAN, Ondřej BEČEV et. al.

Základní údaje

Originální název

The Influence of False Cardiac Feedback on Autonomic Markers of Arousal

Autoři

KUŘÁTKOVÁ, Marie (203 Česká republika, garant, domácí), Eva KOZÁKOVÁ (203 Česká republika, domácí), Radek MAREČEK (203 Česká republika, domácí), Robert ROMAN (203 Česká republika, domácí), Ondřej BEČEV (203 Česká republika, domácí), Lenka SAKÁLOŠOVÁ (703 Slovensko, domácí), Milan BRÁZDIL (203 Česká republika, domácí) a B. MAJCHROWICZ (616 Polsko)

Vydání

Studia Psychologica, Bratislava, Ústav experimentálnej psychológie SAV, 2019, 0039-3320

Další údaje

Jazyk

angličtina

Typ výsledku

Článek v odborném periodiku

Obor

30105 Physiology

Stát vydavatele

Slovensko

Utajení

není předmětem státního či obchodního tajemství

Odkazy

Impakt faktor

Impact factor: 0.537

Kód RIV

RIV/00216224:14740/19:00110679

Organizační jednotka

Středoevropský technologický institut

UT WoS

000490942200001

Klíčová slova anglicky

false cardiac feedback; interoception; heart rate; respiratory rate; autonomic arousal

Příznaky

Mezinárodní význam, Recenzováno
Změněno: 8. 10. 2024 08:38, Ing. Jana Kuchtová

Anotace

V originále

Interoception plays a key role in experiencing emotions, as it provides information about bodily arousal. Cardiac feedback manipulation proved to be a useful tool for exploring interoceptive processes. However, previous research showed inconclusive results on the influence of synchronous and false cardiac feedback on autonomic arousal. In the present study, we measured the influence of accelerated false cardiac feedback on participants' heart rate, respiratory rate and heart rate variability. Furthermore, we were interested in the modulatory effect of interoceptive accuracy measured by the Schandry task. Participants' ECG and respiratory rate were recorded during experimental task involving presentation of synchronous and false auditory cardiac feedback. Contrary to our assumption, false cardiac feedback elicited deceleration of heart rate and reduction of heart rate variability. Interoceptive accuracy had no effect on either variable. According to participant's reports, cardiac and the respiratory deceleration may come from down-regulatory responses to the distorted feedback.

Návaznosti

EF16_013/0001775, projekt VaV
Název: Modernizace a podpora výzkumných aktivit národní infrastruktury pro biologické a medicínské zobrazování Czech-BioImaging
90062, velká výzkumná infrastruktura
Název: Czech-BioImaging