MAKHNEVA, Ekaterina, Zdeněk FARKA, Matěj PASTUCHA, Adam OBRUSNÍK, Veronika HORÁČKOVÁ, Petr SKLÁDAL a Lenka ZAJÍČKOVÁ. Maleic anhydride and acetylene plasma copolymer surfaces for SPR immunosensing. Analytical and Bioanalytical Chemistry. Springer-Verlag, 2019, roč. 411, č. 29, s. 7689-7697. ISSN 1618-2642. Dostupné z: https://dx.doi.org/10.1007/s00216-019-01979-9.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Maleic anhydride and acetylene plasma copolymer surfaces for SPR immunosensing
Autoři MAKHNEVA, Ekaterina (643 Rusko, domácí), Zdeněk FARKA (203 Česká republika, domácí), Matěj PASTUCHA (203 Česká republika, domácí), Adam OBRUSNÍK (203 Česká republika, domácí), Veronika HORÁČKOVÁ (203 Česká republika, domácí), Petr SKLÁDAL (203 Česká republika, domácí) a Lenka ZAJÍČKOVÁ (203 Česká republika, garant, domácí).
Vydání Analytical and Bioanalytical Chemistry, Springer-Verlag, 2019, 1618-2642.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 10406 Analytical chemistry
Stát vydavatele Německo
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 3.637
Kód RIV RIV/00216224:14740/19:00111525
Organizační jednotka Středoevropský technologický institut
Doi http://dx.doi.org/10.1007/s00216-019-01979-9
UT WoS 000502969200009
Klíčová slova anglicky Plasma polymerization; Carboxyl-rich films; Immobilization; Surface plasmon resonance biosensor; Label-free detection
Štítky CF NANO, rivok
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Ing. Monika Szurmanová, Ph.D., učo 466567. Změněno: 8. 10. 2024 10:55.
Anotace
We report on the successful application of carboxyl-rich plasma polymerized (PP) films as a matrix layer for bioreceptor immobilization in surface plasmon resonance (SPR) immunosensing. Composition and chemical properties of the carboxyl-rich PP films deposited from a mixture of maleic anhydride and acetylene were investigated. Changes in the films stored in air, water, and buffer were studied and the involved chemical changes were described. Performance in SPR immunosensing was evaluated on interactions of human serum albumin (HSA) with a specific monoclonal antibody. The comparison with the mixed self-assembled monolayer of mercaptoundecanoic acid and mercaptohexanol (MUA/MCH) and one of the most widely used surfaces for SPR, the 2D and 3D carboxymethylated dextran (CMD), was presented to show the efficacy of plasma polymerized matrix layers for biosensing. The PP film-based SPR immunosensor provided a similar detection limit of HSA (100 ng/mL) as MUA/MCH- (100 ng/mL) and 3D CMD (50 ng/mL)-based sensors. Ho
Návaznosti
LM2015043, projekt VaVNázev: Česká infrastruktura pro integrativní strukturní biologii (Akronym: CIISB)
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, Czech Infrastructure for Integrative Structural Biology
LQ1601, projekt VaVNázev: CEITEC 2020 (Akronym: CEITEC2020)
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, CEITEC 2020
90043, velká výzkumná infrastrukturaNázev: CIISB
VytisknoutZobrazeno: 9. 10. 2024 05:24