POLZER, Stanislav, T. Christian GASSER, Robert VLACHOVSKÝ, Luboš KUBÍČEK, Lukas LAMBERT, Vojtech MAN, Kamil NOVAK, Martin SLAZANSKY, Jiri BURSA a Robert STAFFA. Biomechanical indices are more sensitive than diameter in predicting rupture of asymptomatic abdominal aortic aneurysms. Journal of Vascular Surgery. New York: Mosby Inc., 2020, roč. 71, č. 2, s. "617-626"-"e1-e6", 16 s. ISSN 0741-5214. Dostupné z: https://dx.doi.org/10.1016/j.jvs.2019.03.051.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Biomechanical indices are more sensitive than diameter in predicting rupture of asymptomatic abdominal aortic aneurysms
Autoři POLZER, Stanislav (203 Česká republika, garant), T. Christian GASSER (752 Švédsko), Robert VLACHOVSKÝ (203 Česká republika, domácí), Luboš KUBÍČEK (203 Česká republika, domácí), Lukas LAMBERT (203 Česká republika), Vojtech MAN (203 Česká republika), Kamil NOVAK (203 Česká republika), Martin SLAZANSKY (203 Česká republika), Jiri BURSA (203 Česká republika) a Robert STAFFA (203 Česká republika, domácí).
Vydání Journal of Vascular Surgery, New York, Mosby Inc. 2020, 0741-5214.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 30212 Surgery
Stát vydavatele Spojené státy
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 4.268
Kód RIV RIV/00216224:14110/20:00115438
Organizační jednotka Lékařská fakulta
Doi http://dx.doi.org/10.1016/j.jvs.2019.03.051
UT WoS 000508630800037
Klíčová slova anglicky Aneurysm; Biomechanics; Rupture risk; Predictability; FEM
Štítky 14110121, rivok
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Mgr. Tereza Miškechová, učo 341652. Změněno: 14. 5. 2021 08:00.
Anotace
Objective: Several studies of biomechanical rupture risk assessment (BRRA) showed its advantage over the diameter criterion in rupture risk assessment of abdominal aortic aneurysm (AAA). However, BRRA studies have not investigated the predictability of biomechanical risk indices at different time points ahead of rupture, nor have they been performed blinded for biomechanical analysts. The objective of this study was to test the predictability of the BRRA method against diameter-based risk indices in a quasi-prospective patient cohort study. Methods: In total, 12 women and 31 men with intact AAAs at baseline have been selected retrospectively at two medical centers. Within 56 months, 19 cases ruptured, whereas 24 cases remained intact within 2 to 56 months. This outcome was kept confidential until all biomechanical activities in this study were finished. The biomechanical AAA rupture risk was calculated at baseline using high-fidelity and low-fidelity finite element method models. The capability of biomechanics-based and diameter-based risk indices to predict the known outcomes at 1 month, 3 months, 6 months, 9 months, and 12 months after baseline was validated. Besides common cohort statistics, the area under the curve (AUC) of receiver operating characteristic curves has been used to grade the different rupture risk indices. Results: Up to 9 months ahead of rupture, the receiver operating characteristic analysis of biomechanics-based risk indices showed a higher AUC than diameter-based indices. Six months ahead of rupture, the largest difference was observed with an AUC of 0.878 for the high-fidelity biomechanical risk index, 0.859 for the low-fidelity biomechanical risk index, 0.789 for the diameter, and 0.821 for the sex-adjusted diameter. In predictions beyond 9 months, none of the risk indices proved to be superior. Conclusions: High-fidelity biomechanical modeling improves the predictability of AAA rupture. Asymptomatic AAA patients with high biomechanical AAA rupture risk indices have an increased risk of rupture. Integrating biomechanics-based diagnostic indices may significantly decrease the false-positive rate in AAA treatment.
VytisknoutZobrazeno: 11. 5. 2024 02:30