TICOVÁ, Barbora, Karel NOVOTNÝ a Viktor KANICKÝ. Comparison of different spectral resolution ICP-OES spectrometers for the determination of rare earth elements. Chemical Papers. CHAM: Slovenská akadémia vied, 2019, roč. 73, č. 12, s. 2913-2921. ISSN 0366-6352. Dostupné z: https://dx.doi.org/10.1007/s11696-019-00879-7.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Comparison of different spectral resolution ICP-OES spectrometers for the determination of rare earth elements
Autoři TICOVÁ, Barbora (203 Česká republika, domácí), Karel NOVOTNÝ (203 Česká republika, garant, domácí) a Viktor KANICKÝ (203 Česká republika, domácí).
Vydání Chemical Papers, CHAM, Slovenská akadémia vied, 2019, 0366-6352.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 10406 Analytical chemistry
Stát vydavatele Švýcarsko
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 0.963 v roce 2017
Kód RIV RIV/00216224:14310/19:00113360
Organizační jednotka Přírodovědecká fakulta
Doi http://dx.doi.org/10.1007/s11696-019-00879-7
UT WoS 000488930200005
Klíčová slova anglicky Rare earth elements; Spectral interferences; ICP-OES
Štítky rivok
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Mgr. Marie Šípková, DiS., učo 437722. Změněno: 11. 5. 2020 17:59.
Anotace
This study investigates possible mutual spectral interferences of REEs for three commercially available spectrometers with different spectral resolutions. Comprehensive spectral interference data were obtained by using model solutions of REEs and spectral interference profiles of the most frequently used analytical lines are presented. The interference factors were calculated for line overlap correction and to confirm the effectiveness of the corrections, and model samples containing mixtures of rare earth elements were analyzed. This approach was useful only for spectrometers with low spectral resolution where the spectral interferences were found to be significant. As was expected, considerably better results were obtained by spectrometers with a high spectral resolution, as such corrections were unnecessary. The certified reference material REE-1 (the Strange Lake mine, Quebec, Canada) was used as a real sample representing REE-containing ore. Our results for both types of spectrometer confirm the assumption that high-spectral-resolution spectrometers provide better and more reliable results than low-spectral-resolution spectrometers with corrective factors. Nevertheless, the use of correction factors for the studied analytical lines does lead to improved results in many cases.
Návaznosti
LQ1601, projekt VaVNázev: CEITEC 2020 (Akronym: CEITEC2020)
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, CEITEC 2020
MUNI/A/1288/2017, interní kód MUNázev: Výzkum, vývoj a aplikace v analytické a fyzikální chemii (Akronym: AFCH)
Investor: Masarykova univerzita, Výzkum, vývoj a aplikace v analytické a fyzikální chemii, DO R. 2020_Kategorie A - Specifický výzkum - Studentské výzkumné projekty
VytisknoutZobrazeno: 24. 5. 2024 06:25