KOMENDOVA, Martina, Radovan METELKA a Jiří URBAN. Pulse Biamperometry for Electrochemical Detection in Flow Systems. In Navratil, T Fojta, M Schwarzova, K. XXXVII MODERNI ELEKTROCHEMICKE METODY. USTI NAD LABEM: LENKA SRSENOVA-BEST SERVIS, 2017, s. 104-107. ISBN 978-80-905221-5-2.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Pulse Biamperometry for Electrochemical Detection in Flow Systems
Název česky Pulzní biamperometrie pro elektrochemickou detekci v průtočných systémech
Název anglicky Pulse Biamperometry for Electrochemical Detection in Flow Systems
Autoři KOMENDOVA, Martina, Radovan METELKA (garant) a Jiří URBAN (203 Česká republika, domácí).
Vydání USTI NAD LABEM, XXXVII MODERNI ELEKTROCHEMICKE METODY, od s. 104-107, 4 s. 2017.
Nakladatel LENKA SRSENOVA-BEST SERVIS
Další údaje
Originální jazyk čeština
Typ výsledku Stať ve sborníku
Obor 10406 Analytical chemistry
Stát vydavatele Česká republika
Utajení není předmětem státního či obchodního tajemství
Forma vydání tištěná verze "print"
WWW URL
Kód RIV RIV/00216224:14310/17:00113623
Organizační jednotka Přírodovědecká fakulta
ISBN 978-80-905221-5-2
UT WoS 000432424300023
Klíčová slova anglicky Pulse biamperometry; Microetectrodes; Capillary detector; Dopamine
Štítky rivok
Změnil Změnila: Mgr. Marie Šípková, DiS., učo 437722. Změněno: 14. 4. 2020 13:24.
Anotace
A novel, pulse biamperometric technique was developed for enhancing the intensity of currents measured during electrochemical detection in flow systems. Two polarizable elctrodes in form of microfibers made of carbon platinum or their combination were utilized for biamperometric detection of dopamine in capillary detectors. Using a sequence of positive and negative potentials, measured signals were two orders of magnitude higher than those obtained for direct biamperometry. Such amplification resulted in forty times increase in sensitivity for dopamine detection. In a pulse mode, the passivation of electrodes was significantly reduced and the repeatability of individiual injections was markedly imporved.
Anotace anglicky
A novel, pulse biamperometric technique was developed for enhancing the intensity of currents measured during electrochemical detection in flow systems. Two polarizable elctrodes in form of microfibers made of carbon platinum or their combination were utilized for biamperometric detection of dopamine in capillary detectors. Using a sequence of positive and negative potentials, measured signals were two orders of magnitude higher than those obtained for direct biamperometry. Such amplification resulted in forty times increase in sensitivity for dopamine detection. In a pulse mode, the passivation of electrodes was significantly reduced and the repeatability of individiual injections was markedly imporved.