LATTA, Peter, Z. STARCUK, Martin KOJAN, M.L.H. GRUWEL, B. TOMANEK, S. TRATTNIG a V. JURAS. Simple compensation method for improved half-pulse excitation profile with rephasing gradient. MAGNETIC RESONANCE IN MEDICINE. HOBOKEN: WILEY-BLACKWELL, roč. 84, č. 4, s. 1796-1805. ISSN 0740-3194. doi:10.1002/mrm.28233. 2020.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Simple compensation method for improved half-pulse excitation profile with rephasing gradient
Autoři LATTA, Peter (703 Slovensko, garant, domácí), Z. STARCUK, Martin KOJAN (703 Slovensko, domácí), M.L.H. GRUWEL, B. TOMANEK, S. TRATTNIG a V. JURAS.
Vydání MAGNETIC RESONANCE IN MEDICINE, HOBOKEN, WILEY-BLACKWELL, 2020, 0740-3194.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 30103 Neurosciences
Stát vydavatele Spojené státy
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 4.668
Kód RIV RIV/00216224:14740/20:00116481
Organizační jednotka Středoevropský technologický institut
Doi http://dx.doi.org/10.1002/mrm.28233
UT WoS 000561641400001
Klíčová slova anglicky eddy current correction; gradients; half-pulse excitation; UTE imaging
Štítky CF MAFIL, rivok
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Mgr. Pavla Foltynová, Ph.D., učo 106624. Změněno: 11. 3. 2021 18:03.
Anotace
Purpose To improve the slice profile quality obtained by RF half-pulse excitation for 2D-UTE applications. Methods The overall first-order and zero-order phase errors along the slice-selection direction were obtained with the help of an optimization task to minimize the out-of-slice signal contamination from the calibration 1-dimenisonal (1D) profile data. The time-phase-error evolution was approximated from the k-space readout data, which were acquired primarily for correction of the readout trajectories during data regridding to the rectilinear grids. The correction of the slice profile was achieved by rephasing gradient pulses applied immediately after the end of excitation. The total prescan calibration typically took less than 2 minutes. Results The improved image quality using the proposed calibration method was demonstrated both on phantoms and on ankle images obtained from healthy volunteers. It was demonstrated that calibration can be performed either as a separate water phantom measurement or directly as a prescan procedure. Conclusion The slice-profile distortion from the half-pulse excitation could substantially affect the overall fidelity of 2D-UTE images. The presented experiments proved that the image quality could be substantially increased by application of the proposed slice-correction method.
Návaznosti
LM2015062, projekt VaVNázev: Národní infrastruktura pro biologické a medicínské zobrazování
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, National research infrastructure for biological and medical imaging
LQ1601, projekt VaVNázev: CEITEC 2020 (Akronym: CEITEC2020)
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, CEITEC 2020
VytisknoutZobrazeno: 20. 4. 2024 01:48