GAJDAR, J, Tomáš GONĚC, J JAMPILEK, Marie BRÁZDOVÁ, Z BABKOVA, Miroslav FOJTA, J BAREK a J FISCHER. Voltammetry of a Novel Antimycobacterial Agent 1-Hydroxy-N-(4-nitrophenyl)naphthalene-2-carboxamide in a Single Drop of a Solution. Electroanalysis. WEINHEIM: WILEY-VCH Verlag GmbH, 2018, roč. 30, č. 1, s. 38-47. ISSN 1040-0397. Dostupné z: https://dx.doi.org/10.1002/elan.201700547. |
Další formáty:
BibTeX
LaTeX
RIS
@article{1726877, author = {Gajdar, J and Goněc, Tomáš and Jampilek, J and Brázdová, Marie and Babkova, Z and Fojta, Miroslav and Barek, J and Fischer, J}, article_location = {WEINHEIM}, article_number = {1}, doi = {http://dx.doi.org/10.1002/elan.201700547}, keywords = {Hydroxynaphthalene-2-carboxanilide; Microcell; Single drop analysis; Voltammetry}, language = {eng}, issn = {1040-0397}, journal = {Electroanalysis}, title = {Voltammetry of a Novel Antimycobacterial Agent 1-Hydroxy-N-(4-nitrophenyl)naphthalene-2-carboxamide in a Single Drop of a Solution}, volume = {30}, year = {2018} }
TY - JOUR ID - 1726877 AU - Gajdar, J - Goněc, Tomáš - Jampilek, J - Brázdová, Marie - Babkova, Z - Fojta, Miroslav - Barek, J - Fischer, J PY - 2018 TI - Voltammetry of a Novel Antimycobacterial Agent 1-Hydroxy-N-(4-nitrophenyl)naphthalene-2-carboxamide in a Single Drop of a Solution JF - Electroanalysis VL - 30 IS - 1 SP - 38-47 EP - 38-47 PB - WILEY-VCH Verlag GmbH SN - 10400397 KW - Hydroxynaphthalene-2-carboxanilide KW - Microcell KW - Single drop analysis KW - Voltammetry N2 - The aim of this study is the development of a miniaturized voltammetric method for the determination of an antimycobacterial agent 1-hydroxy-N-(4-nitrophenyl)naphthalene-2-carboxamide (HNN) in a single drop (20L) of a solution by cathodic and anodic voltammetry at a glassy carbon electrode. Cyclic voltammetry was used to investigate its redox properties followed by the optimization of differential pulse voltammetric determination in a regular 10mL volume. The optimal medium for the analytical application of both cathodic and anodic voltammetry was found to be Britton-Robinson buffer pH7.0 and dimethyl sulfoxide (9:1, v/v). HNN gave one cathodic peak at around -0.6V and one anodic peak at around +0.2V vs. Ag|AgCl (3molL(-1) KCl) reference electrode. Determination of HNN in a 10mL volume gave the limit of quantification around 10nmolL(-1) by both adsorptive stripping anodic and cathodic voltammetry. Afterwards, miniaturized voltammetric methods in a single drop of solution (20L) were investigated. This approach requested some modifications of the cell design and voltammetric procedures. A novel method of removing dissolved oxygen in a single drop had to be developed and tested. Developed miniaturized voltammetric methods gave parameters comparable to the determination of HNN in 10mL. The applicability of the miniaturized method was verified by the determination of HNN in a drop of a bacterial growth medium. ER -
GAJDAR, J, Tomáš GONĚC, J JAMPILEK, Marie BRÁZDOVÁ, Z BABKOVA, Miroslav FOJTA, J BAREK a J FISCHER. Voltammetry of a Novel Antimycobacterial Agent 1-Hydroxy-N-(4-nitrophenyl)naphthalene-2-carboxamide in a Single Drop of a Solution. \textit{Electroanalysis}. WEINHEIM: WILEY-VCH Verlag GmbH, 2018, roč.~30, č.~1, s.~38-47. ISSN~1040-0397. Dostupné z: https://dx.doi.org/10.1002/elan.201700547.
|