MUKHERJEE, A., A.M. ASHRAFI, P. SVEC, L. RICHTERA, Jan PŘIBYL, M. BRTNICKY, J. KYNICKY a V. ADAM. The Effect of Synthesis Procedure on Hydrogen Peroxidase-Like Catalytic Activity of Iron Oxide Magnetic Particles. Applied Sciences-Basel. BASEL, SWITZERLAND: MDPI AG, roč. 10, č. 19, s. 6756-6767. ISSN 2076-3417. doi:10.3390/app10196756. 2020.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název The Effect of Synthesis Procedure on Hydrogen Peroxidase-Like Catalytic Activity of Iron Oxide Magnetic Particles
Autoři MUKHERJEE, A., A.M. ASHRAFI, P. SVEC, L. RICHTERA, Jan PŘIBYL (203 Česká republika, garant, domácí), M. BRTNICKY, J. KYNICKY a V. ADAM.
Vydání Applied Sciences-Basel, BASEL, SWITZERLAND, MDPI AG, 2020, 2076-3417.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 10403 Physical chemistry
Stát vydavatele Švýcarsko
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 2.679
Kód RIV RIV/00216224:14740/20:00118358
Organizační jednotka Středoevropský technologický institut
Doi http://dx.doi.org/10.3390/app10196756
UT WoS 000586389800001
Klíčová slova anglicky magnetic nanoparticle; nanozyme; chronoamperometry; biosensor; peroxidase-like activity
Štítky CF CRYO, CF NANO, rivok
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Mgr. Pavla Foltynová, Ph.D., učo 106624. Změněno: 9. 3. 2021 19:44.
Anotace
A comparative study was carried out using magnetic nanoparticles (MNPs) for the fabrication of non-enzymatic sensors for the continuous and rapid detection and monitoring of H2O2. Various MNPs, differing in terms of their synthesis procedure and modification, were synthesized and characterized by different techniques. The electrochemical catalytic activity of the synthesized MNPs toward the reduction in H2O2 was investigated by cyclic voltammetry. The naked MNPs showed the highest catalytic activity among all the synthesized MNPs. The biosensor based on the naked MNPs was then applied in the determination of H2O2 using chronoamperometry. The parameters such as the applied cathodic potential and the amount of MNPs on the developed biosensor were optimized. Moreover, the analytical figures of merit, including reproducibility (RSD = 6.14%), sensitivity (m = 0.0676 mu A mu M-1), limit of detection (LOD) = 27.02 mu mol L-1, and limit of quantification (LOQ) = 89.26 mu mol L-1 of the developed biosensor indicate satisfactory analysis. Finally, MNPs were successfully utilized for the determination of H2O2 in milk.
Návaznosti
LM2018127, projekt VaVNázev: Česká infrastruktura pro integrativní strukturní biologii (Akronym: CIISB)
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, Czech Infrastructure for Integrative Structural Biology
LQ1601, projekt VaVNázev: CEITEC 2020 (Akronym: CEITEC2020)
Investor: Ministerstvo školství, mládeže a tělovýchovy ČR, CEITEC 2020
VytisknoutZobrazeno: 20. 4. 2024 14:38