J 2021

A Simple Teabag Equilibrium Passive Sampler using hydrophilic divinylbenzene sorbent for contaminants of emerging concern in the marine environment

VANRYCKEGHEM, Francis; Steve HUYSMAN; Foppe SMEDES; Herman VAN LANGENHOVE; Lynn VANHAECKE et. al.

Základní údaje

Originální název

A Simple Teabag Equilibrium Passive Sampler using hydrophilic divinylbenzene sorbent for contaminants of emerging concern in the marine environment

Autoři

VANRYCKEGHEM, Francis (56 Belgie); Steve HUYSMAN (56 Belgie); Foppe SMEDES (528 Nizozemské království, garant, domácí); Herman VAN LANGENHOVE (56 Belgie); Lynn VANHAECKE (56 Belgie) a Kristof DEMEESTERE (56 Belgie)

Vydání

Science of the Total Environment, Amsterdam, Elsevier Science, 2021, 0048-9697

Další údaje

Jazyk

angličtina

Typ výsledku

Článek v odborném periodiku

Obor

10511 Environmental sciences

Stát vydavatele

Nizozemské království

Utajení

není předmětem státního či obchodního tajemství

Odkazy

Impakt faktor

Impact factor: 10.754

Kód RIV

RIV/00216224:14310/21:00122209

Organizační jednotka

Přírodovědecká fakulta

UT WoS

000655615100019

EID Scopus

2-s2.0-85102123447

Klíčová slova anglicky

Micropollutant; Passive sampling; Sampling rate; Equilibrium partitioning; Teabag; Marine environment

Štítky

Příznaky

Mezinárodní význam, Recenzováno
Změněno: 6. 6. 2025 09:46, Mgr. Michaela Hylsová, Ph.D.

Anotace

V originále

A promising concept for sampling contaminants of emerging concern (CECs) using a home-made Simple Teabag Equilibrium Passive Sampler (STEPS) containing hydrophilic divinylbenzene (h-DVB) sorbent is presented and evaluated for application in estuarine systems. The uptake of a multi-class mixture of CECs with a broad polarity range (Log P ranging from -0.1 to 9.9) was investigated in static exposure batch experiments. Sampling rates (R-s) and equilibrium partitioning coefficients (K-sw) were determined for up to 74 CECs. Fast uptake (R-s = 0.3-12 L d(-1)) was noticed and the STEPS attained equilibrium partitioning after 1 to 2 weeks of exposure, with Log K-sw ranging from 4.1 to 6.5 L kg(-1). Field application of this novel h-DVB containing STEPS, followed by ultra-high performance liquid chromatography coupled to high-resolution Orbitrap mass spectrometry, revealed the presence of up to 40 steroidal hormones, (alkyl)phenols, phthalates, pharmaceuticals, personal care products, and pesticides in the Belgian Part of the North Sea. The measured trace concentrations (from 0.003 ng L-1 to 1.9 mu g L-1) and good precision (average RSD < 30%, n = 3) demonstrate the STEPS as fit-for-purpose for micropollutant analysis in the marine environment.

Návaznosti

EF16_013/0001761, projekt VaV
Název: RECETOX RI
90051, velká výzkumná infrastruktura
Název: RECETOX II