ŠIKOLOVÁ, Soňa, Milan URÍK, Dagmar HOŠNOVÁ, Vít KRUNTORÁD, Michal BARTOŠ, Oldřich MOTYKA a Petr JABANDŽIEV. Two Bonebridge bone conduction hearing implant generations: audiological benefit and quality of hearing in children. European Archives of Oto-Rhino-Laryngology. New York: Springer, 2022, roč. 279, č. 7, s. 3387-3398. ISSN 0937-4477. Dostupné z: https://dx.doi.org/10.1007/s00405-021-07068-x.
Další formáty:   BibTeX LaTeX RIS
Základní údaje
Originální název Two Bonebridge bone conduction hearing implant generations: audiological benefit and quality of hearing in children
Autoři ŠIKOLOVÁ, Soňa (203 Česká republika, domácí), Milan URÍK (703 Slovensko, garant, domácí), Dagmar HOŠNOVÁ (203 Česká republika, domácí), Vít KRUNTORÁD (203 Česká republika, domácí), Michal BARTOŠ (203 Česká republika, domácí), Oldřich MOTYKA (203 Česká republika) a Petr JABANDŽIEV (203 Česká republika, domácí).
Vydání European Archives of Oto-Rhino-Laryngology, New York, Springer, 2022, 0937-4477.
Další údaje
Originální jazyk angličtina
Typ výsledku Článek v odborném periodiku
Obor 30206 Otorhinolaryngology
Stát vydavatele Spojené státy
Utajení není předmětem státního či obchodního tajemství
WWW URL
Impakt faktor Impact factor: 2.600
Kód RIV RIV/00216224:14110/22:00124985
Organizační jednotka Lékařská fakulta
Doi http://dx.doi.org/10.1007/s00405-021-07068-x
UT WoS 000695739900001
Klíčová slova anglicky Active transcutaneous bone conduction implant; Children; Quality of lif; Atresia; Localisation; Hearing outcomes
Štítky 14110317, 14110319, rivok
Příznaky Mezinárodní význam, Recenzováno
Změnil Změnila: Mgr. Tereza Miškechová, učo 341652. Změněno: 14. 2. 2024 14:15.
Anotace
Purpose The study aimed to evaluate audiological benefits, quality of hearing and safety of two Bonebridge generation: BCI601 and BCI602 (MED-EL, Innsbruck, Austria) in children. Methods Twelve children were implanted: five BCI601 and seven BCI602 comprising of ten conductive hearing loss, and two single sided deaf SSD subjects. Audiological outcomes tested were sound field audiometry, functional gain, speech recognition threshold (SRT50), speech recognition in noise (SPRINT) and localisation abilities. Subjective measures were Speech, Spatial and Qualities of Hearing Scale (SSQ12). Results The mean FG with the BCI601 was 25.0 dB and with the BCI602 28.0 dB. The benefit in SRT50 was 23.2 dB and 33.8 dB, respectively. The mean benefit in SPRINT was 15% and 6.7% and the localisation ability improved from 33.3° to 16° and from 26.2° to 17.6°, respectively. The two SSD subjects reported a FG of 17 dB, a benefit in SRT50 of 22.5 and a benefit in SPRINT of 20%. Subjective outcomes improved significantly and even exceeded the values of their age-and sex matched normal hearing peers. One revision was reported: a retroauricular emphysema above the implant occurred 12 months post-OP, it was resolved operatively with the implant still being functional. Conclusion The pediatric cohort reports significant audiological benefit, even exceeding that of the age- and sex matched control. The combination of the high safety and audiological benefit makes the Bonebridge a comfortable and effective option in hearing rehabilitation in children.
Návaznosti
MUNI/A/1118/2020, interní kód MUNázev: Ztráta sluchu v dětském věku - příčiny, diagnostika, možnosti rehabilitace V.
Investor: Masarykova univerzita, Ztráta sluchu v dětském věku - příčiny, diagnostika, možnosti rehabilitace V.
MUNI/A/1132/2021, interní kód MUNázev: Ztráta sluchu v dětském věku - příčiny, diagnostika, možnosti rehabilitace VI.
Investor: Masarykova univerzita, Ztráta sluchu v dětském věku - příčiny, diagnostika, možnosti rehabilitace VI.
MUNI/A/1365/2022, interní kód MUNázev: Analýza bakteriálních původců akutního středoušního zánětu pomocí moderních sekvenačních technik
Investor: Masarykova univerzita, Analýza bakteriálních původců akutního středoušního zánětu pomocí moderních sekvenačních technik
VytisknoutZobrazeno: 24. 4. 2024 17:17